Page 20 PROGRAMMING
BASIC PROGRAMMING
BATTERY ALARM
THRESHOLD ON
TERMINALS +
AND –
(INST)
(mV, from 1 to 5 digits;
factory default 11500)
[ ]
REPLACE
BATTERY
ALARM*
(INST)
* 5HL-600 / 5HL-603
only
disabled alarm
enabled alarm
AUTOMATIC TEST
DATA
(INST)
Frequency
(days, from 1 to 9; factory default 3)
Time
(hhmm from 0000 to 2359;
factory default 0400)
Automatic
test alarm
automatic test disabled
automatic test enabled (EN 81-28:2018)
automatic test enabled (EN 81-28:2004)
Make a test call
manually
PROTOCOLS
IDENTIFICATION
CODE
(INST)
Esse-ti
(identification code) [ ]
P100
SPEAKER UNITS
VOLUME
(INST/OPER)
loudspeaker
(from 1 to
9; factory
default 3)
microphone
(from 1 to
9; factory
default 5)
[
]
MESSAGES
VOLUME
(INST/OPER)
(from 1 to 4; factory default 3; 4=loudspeaker
volume, 3=¾ of loudspeaker volume, 2=½ of
loudspeaker volume, 1=¼ of loudspeaker volume)
LISTEN TO THE
PROGRAMMING
AGAIN
(INST)
... (programming code prefix)
RESTORE
FACTORY
SETTINGS
(INST)

Related product manuals