Fire Alarm Computer 8000C / M
8.7 Definition of the Primary loop number
Individual assemblies of the FACP 8000C / M can be switched on/off with the internal primary loop
number through the control panel keyboard or programmed with the customer data editor. This
internal primary loop number is composed of the control panel number, the slot and the assembly
number.
Example: FACP 8000C / M (Panel number 01)
1
2
B
1
2
3
4
5
D
B
Fig. 22: Example FACP 8000C Example FACP 8000M
0 1
2
3
Subassembly number of the Basic-, Field device-
or extension module
Slot number: Basic module = No. 1
Basic module Slot 1 = No. 2
Basic module Slot 2 = No. 3 (only 8000M)
Number of the Fire Alarm Panel (01 to max. 31)
L
ocation of plug in cards
P
rimary loop number 0123
P
rimary loop number 0113
P
rimary loop number 0131