Questions and Answers

  • T
    Thomas BowenSep 10, 2025
    What to do if eta plus ELC X6-60 displays 'Measurement' error?
    • C
      Collin McguireSep 12, 2025
      If your eta plus Controller shows a 'Measurement' error, it indicates problems with the internal measurement circuits. Check for a short in the lamp circuit.
  • T
    tyler46Aug 22, 2025
    Why is my eta plus ELC X6-60 Controller showing a 'Temp high' error?
    • J
      Jason RamseyAug 23, 2025
      A 'Temp high' error on your eta plus Controller indicates that the ambient or internal temperature is too high. Verify the ambient temperature and check the cabinet fans for proper airflow direction. Consider changing the filter mats.
  • C
    Christopher MatthewsAug 25, 2025
    How to fix Mains volt error on eta plus ELC X6-60 Controller?
    • K
      Katie MorganAug 25, 2025
      If you're seeing a 'Mains volt' error on your eta plus Controller, it means the input voltage measurement has detected mains voltage drops or fluctuations. You should check the connections and the mains voltage.
  • R
    Rachel MillsAug 26, 2025
    What causes Earthfault on eta plus ELC X6-60 and how to resolve it?
    • D
      Denise DiazAug 27, 2025
      An 'Earthfault' error on your eta plus Controller means the insulation resistance between the lamp circuitry and earth is lower than 200 kOhm. Inspect the lamp wiring and insulation resistance.
  • B
    Brandon AllenAug 28, 2025
    What does 'Over volt' mean on eta plus Controller, and how can I fix it?
    • C
      Christine HooperAug 28, 2025
      An 'Over volt.' error on the eta plus Controller indicates that a short peak overvoltage on the lamp exceeds the nominal ignition voltage during ignition or operation. This might be due to an internal problem with the ELC or damaged cables in the lamp circuitry. Check the lamp wiring for insulation defects.
  • A
    Anita DownsAug 29, 2025
    What to do if eta plus ELC X6-60 Controller shows 'Lamp v.hi' error?
    • M
      Michael BeckerAug 29, 2025
      If your eta plus Controller displays a 'Lamp v.hi' error, it means the lamp voltage exceeds a threshold critical for the ELC. This usually indicates that the lamp type is incorrect. Verify the lamp type and lamp connectors/sockets, and consider switching the lamp.
  • D
    Dana MillerSep 18, 2025
    What does 'CanIntern' error mean on eta plus ELC X6-60 Controller?
    • A
      Amy SolisSep 18, 2025
      A 'CanIntern' error on your eta plus Controller indicates interference in modul-internal communication. Check the internal wiring.
  • R
    randersonSep 12, 2025
    What does 'PLow' mean on eta plus Controller and how to fix it?
    • B
      Benjamin LambertSep 12, 2025
      A 'PLow' error on your eta plus Controller means the lamp extinguishes, possibly due to cooling being too strong or a lamp defect. Reduce cooling or replace the lamp. Also, check the lamp wiring.
  • K
    Kelli JacksonSep 8, 2025
    What does 'Internal' error mean on eta plus ELC X6-60 Controller and how to resolve it?
    • L
      Lori RogersSep 8, 2025
      An 'Internal' error on your eta plus Controller indicates problems with internal communication between controllers or a failed “self-check” of the controllers. Try switching off and on the 24V supply.
  • K
    Kenneth RichardsonSep 5, 2025
    What causes a 'Bus error' on eta plus ELC X6-60?
    • M
      macdonaldangelaSep 5, 2025
      A 'Bus error' on the eta plus Controller means the field bus connection failed during lamp operation. Inspect the bus termination and connector contact.

Summary

Safety Information

Safety Advice

General safety rules for installation, repair, and operation.

Correct Operation Guidelines

Defines intended use and liability for misuse.

Installation Procedures

Casing Mounting

Describes methods for mounting the ELC casing, including T-slots and stacking.

Electrical Connections

Covers the process of connecting electrical components to the ELC.

BUS Configuration

Covers settings for BUS configuration, addresses, and parameters.

Setting BUS Address

Guides on setting up the BUS address using the SET button.

BUS Connection and Error Check

Describes how to check BUS connection and interpret display error messages.

Setting Lamp Power via BUS

Explains how to set lamp power using BUS communication.

Operation Guide

Switching On the ELC

Provides special procedures for initial operation after storage.

Activating Safety Circuits

Explains how to activate the safety relay and initialisation signal.

Switching On the Lamp

Details the process of writing lamp power and igniting the lamp.

Monitoring, Error Handling, and Repair

Warning Messages

Explains the two groups of warning bits in the Warning Register.

Error Handling

Covers error messages, display indicators, and troubleshooting.

Error Messages and Troubleshooting

Connects display messages to error register bits and provides corrective actions.

Resetting the Error Register

Explains the procedure to reset the error register using the Clear Error bit.

Technical Data

ELC X4 Specifications

Details power, electrical, mechanical, and environmental specs for ELC X4.

eta plus ELC X6-60 Specifications

General IconGeneral
Brandeta plus
ModelELC X6-60
CategoryController
LanguageEnglish

Related product manuals