EasyManua.ls Logo

eta plus ELC X Series - User Manual

Default Icon
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
UV-
TECHNOLOGY
Technical Documentation
ELC
®
X-Series
GB
eta plus electronic gmbh
Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22 - 60 02-80, Fax +49 (0) 70 22 6 58 54
Postfach 1411, D-72604 Nürtingen, e-mail: info@eta-uv.de
––––––––––––––––––––––––––––
Eingetragen unter HRB 724321 AG Stuttgart, USt.-Id.-Nr. DE 146267800
Geschäftsführer: Dr. Peter Schwarz-Kiene

Table of Contents

Questions and Answers

  • S
    stephanie03Sep 10, 2025
    What to do if eta plus ELC X Controller displays 'Measurement' error?
    • B
      Bonnie SmithSep 12, 2025
      If your eta plus Controller shows a 'Measurement' error, it indicates problems with the internal measurement circuits. Check for a short in the lamp circuit.
  • K
    knoxbrianAug 23, 2025
    Why is my eta plus Controller showing a 'Temp high' error?
    • N
      Nicole SchwartzAug 23, 2025
      A 'Temp high' error on your eta plus Controller indicates that the ambient or internal temperature is too high. Verify the ambient temperature and check the cabinet fans for proper airflow direction. Consider changing the filter mats.
  • J
    joseph32Aug 25, 2025
    How to fix Mains volt error on eta plus ELC X?
    • S
      Shannon YatesAug 25, 2025
      If you're seeing a 'Mains volt' error on your eta plus Controller, it means the input voltage measurement has detected mains voltage drops or fluctuations. You should check the connections and the mains voltage.
  • E
    eharrisonAug 27, 2025
    What causes Earthfault on eta plus ELC X Controller and how to resolve it?
    • B
      Billy VaughnAug 27, 2025
      An 'Earthfault' error on your eta plus Controller means the insulation resistance between the lamp circuitry and earth is lower than 200 kOhm. Inspect the lamp wiring and insulation resistance.
  • A
    acunninghamAug 28, 2025
    What does 'Over volt' mean on eta plus ELC X, and how can I fix it?
    • M
      moniquebrownAug 28, 2025
      An 'Over volt.' error on the eta plus Controller indicates that a short peak overvoltage on the lamp exceeds the nominal ignition voltage during ignition or operation. This might be due to an internal problem with the ELC or damaged cables in the lamp circuitry. Check the lamp wiring for insulation defects.
  • T
    turnerjamesAug 29, 2025
    What to do if eta plus ELC X Controller shows 'Lamp v.hi' error?
    • E
      Emily KnightAug 29, 2025
      If your eta plus Controller displays a 'Lamp v.hi' error, it means the lamp voltage exceeds a threshold critical for the ELC. This usually indicates that the lamp type is incorrect. Verify the lamp type and lamp connectors/sockets, and consider switching the lamp.
  • J
    josemcclainSep 18, 2025
    What does 'CanIntern' error mean on eta plus ELC X?
    • C
      Colin WardSep 18, 2025
      A 'CanIntern' error on your eta plus Controller indicates interference in modul-internal communication. Check the internal wiring.
  • J
    Jesse HortonSep 12, 2025
    What does 'PLow' mean on eta plus Controller and how to fix it?
    • H
      heatherjonesSep 12, 2025
      A 'PLow' error on your eta plus Controller means the lamp extinguishes, possibly due to cooling being too strong or a lamp defect. Reduce cooling or replace the lamp. Also, check the lamp wiring.
  • G
    Garrett DickersonSep 8, 2025
    What does 'Internal' error mean on eta plus ELC X Controller and how to resolve it?
    • C
      Cindy KleinSep 8, 2025
      An 'Internal' error on your eta plus Controller indicates problems with internal communication between controllers or a failed “self-check” of the controllers. Try switching off and on the 24V supply.
  • S
    Sally KingSep 5, 2025
    What causes a 'Bus error' on eta plus Controller?
    • P
      Pamela GonzalezSep 5, 2025
      A 'Bus error' on the eta plus Controller means the field bus connection failed during lamp operation. Inspect the bus termination and connector contact.

Summary

Safety

Safety advice

Provides essential safety guidelines for installation and operation.

Correct operation

Defines the intended use and limitations of the ELC.

Installation

Electrical Connections

Details all electrical connection points, including power, control, and bus interfaces.

Configuration

Covers setting up the ELC, including BUS addresses and parameters.

Operation of the ELC

Lamp Operation

Details switching the lamp on, dimming, and switching off.

Monitoring, Warning, Error, and Repair

Error Handling and Troubleshooting

Covers error messages, display indicators, and reset procedures.

eta plus ELC X Series Specifications

General IconGeneral
Brandeta plus
ModelELC X Series
CategoryController
LanguageEnglish

Related product manuals