6 Technical Data page 67
ELC X-Series-V1.5-06.18-GB subject to technical alterations
6.5 ELC X16, X16B, X16i, X16F
Output power characteristics
Type
ELC X16-140
ELC X16F-140
ELC X16B-140
ELC X16i-140
Power factor
typ. > 97%
Power efficiency
typ. > 94%
Nominal power range
3200 W 16000 W
Electrical characteristics
Type
ELC X16-140
ELC X16F-140
ELC X16B-140
ELC X16i-140
Nominal supply voltage
400 V 480 V
440 V
400 V 480 V
Operating supply voltage range
400 V 480 V
Nominal supply current
22 A 18 A per module
20 A per module
22 A 18 A per module
Max. supply current
24 A per module
Line protection*
min. 25 A per module
Internal fuse at mains input
(F200, F203)
SIBA 5012434.30 URZ 30 A / 690 V / 14x51mm or comparable type
class gRL (gS)
Arcing-I²t-Value 190 A²s, Total I²t-Value (@AC 690 V) 1400 A²s
Mains frequency
50 / 60 Hz
Min. mains voltage (shut down
voltage)
320 V
Output power reduction in case
of low mains voltage (also see
paragraph 3.4.4)
from approx. 360 V 320 V: 40 W / V
Abs. max. mains voltage
528 V
Leakage current
ca. 10 mA per module
Insulation resistance between
primary and PE
> 30 MΩ
Discharching time of residual
voltage after mains
disconnection
according to label above mains connector in the ballast
Charge time (minimum time
between switch on of the ELC
and starting the lamp)
16 s
*Line protection: automatic cut-out characteristic C