3 Installation page 7
ELC X-Series-V1.5-06.18-GB subject to technical alterations
3.2.2 Profile of the cable gasket X4 X8
The IP protection level given in chapter 6 is only guaranteed if every cable’s lead-in is
completely sealed.
For this purpose the following preconditions have to be fulfilled:
Use cables of the nominal diameters given in Table 1.
Cable gasket
Cable
diameter
Connector
designation
Function
Connector
no. of pins
Connector
type eta
ID.:
Cable
length
(gasket to
connector)
Plug
contact
7.5mm
±5%
X3
Bus out
(T-
coupler)
3
9546
120mm
blank
wire or
ferrule
9.3mm ±
5%
X600 (1, 3)
Lamp
output
3
9532
155mm
blank
wire or
ferrule
4.9mm ±
5%
X600 (2)
PE
5.2mm ±
5%
X806
Control
7
9535
130mm
ferrule
7.5mm ±
5%
X1
Bus in
4
9545
120mm
blank
wire or
ferrule
6.7mm ±
5%
X805
Control
11
9536
130mm
ferrule
7.5mm ±
5%
X2
Bus out
4
9545
120mm
blank
wire or
ferrule
12.2mm ±
5%
X100
Mains
input (2 x
Phase, 2 x
PE)
4
9531
490mm
blank
wire or
ferrule
Table 1: Cable connection parameters X4-X8