For better stability, slide individual parts of the tube to each other so that the tube is as
short as possible. Always store the oor nozzle in the carpet setting (with the brush inside)
to avoid bending of the bristle.
V. MAINTENANCE
Store the vacuum cleaner at a dry place, far enough from heat sources (e.g. replace,
stove, heating element) and protect it against weather conditions (e.g. rain, sunshine).
Treat the appliance surface with a soft damp cloth, do not use coarse and aggressive
detergents! For failure-free operation of the vacuum cleaner we recommend checking the
aggregate and the general condition of the vacuum cleaner in a specialized service centre
after 300 hours of operation, but not later than in 3 years. Store the appliance properly
cleaned at a dry, dust free place out of reach of children and incapacitated people.
Floor nozzle
It is recommended to check the brushes or collectors for possible impurities. If there are
some impurities, remove them.
TURBO nozzle
If hair or threads are twisted around the mounting of the drive shaft and if they cannot be
removed in the way described above, the impurities have to be removed by dismantling
the nozzles. In the lower part remove the cover. Now you can clean the nozzle using a
suitable tool (eg tweezers). Insert the lid to the nozzle in the opposite direction (you will
hear a snapping sound).
VI. TROUBLESHOOTING
Problem Cause Solution
Motor won‘t start Power supply not
connected
The
button is not
switched on
Check the cord, plug and the socket
Press the switch button
The lid cannot be
closed - safety
lock activated
Dust lter / adapter not
inserted properly
Holder inserted incorrectly
in the suction space of the
vacuum cleaner
Check/repair fastening of the carton
front / adapter
Check/repair insertion of the holder
in the suction space of the vacuum
cleaner
Suction power is
insufcient
Regulation is at MIN
Open sucking
Dust bag is full
Clogged micro lters
Nozzle, sucking hose or
Hose is clogged.
Set the regulator to MAX.
Close the opening on the hose holder
Replace the dust bag
Replace or clean the micro lters
Remove the blocking objects
The cable cannot
be wound in the
entire length
Twisted cable Straighten the cable Take out about
50 cm of the cable and push again the
button