ETC Installation Guide
ColorSource Linear v1.7
Environment
The ColorSource Linear operates in ambient temperatures of 0°C–4C and
comes with a variable-speed fan. The ColorSourceLinear is for indoor use
only.
Maximum recommended ambient operating temperature: Ta=40°C
(104°F)
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 8C (17F)
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 36°C (97°F)
External Temperature (steady state achieved) at 2C (77°F): 48°C
(118°F)
Electrical
Operates between 100V and 240VAC at a frequency of 50/60Hz.
Maximum power consumption:
-
Linear 1: 120 W
-
Linear 2: 240 W
-
Linear 4: 480 W
Up to 9 cells (0.5 m segments) may be linked via power thru connector.
Up to 10 cells (0.5 m segments) total per circuit when used with an
R20Relay Module or Unison Echo Relay Panel. Consult breaker trip
curves when used with other equipment. Requires power from a non-
dimmable source.
Inrush (Linear 1/Linear 2/Linear 4):
-
120 V: 35 A/35.6 A/67.5 A (first half-cycle)
-
240 V: 49 A/85.6 A/153 A (first half-cycle)
ColorSource Linear Page 3 of 20 ETC