TECHNISCHE DATEN / SPECIFICATIONS
MODELL
Ausgangsleistung BDA @ 14,4V 1% THD
Output Power
Ausgangsleistung gebrückt
Bridge output power
THD+N
BDA @ 14,4V 1% THD
gemessen
measured
@ 14,4V 1% THD
(Gesamtklirrfaktor + Rauschen)
THD+N (total harmonic dist. + noise)
@ 1WRMS 13,6V / 4Ohm
THD+N (Gesamtklirrfaktor + Rauschen)
THD+N (total harmonic dist. + noise)
@ 5WRMS 13,6V / 4Ohm
Maße Breite / width
Dimensions Länge / length
Höhe / height
Crossover
MINI 300.2
0,009%
0,01%
2x 185W RMS @ 4W
2x 310W RMS @ 2W
1x 620W RMS @ 4W
183mm
146mm
50mm
HP and/or LP
HP 15-300Hz
LP 30Hz-300Hz
MINI 150.4
0,009%
0,007%
4x 100W RMS @ 4W
4x 155W RMS @ 2W
2x 310W RMS @ 4W
183mm
146mm
50mm
CH 1/2
HP 15-300Hz (x1)
LP 300Hz-6kHz (x20)
CH 3/4
HP 15-300Hz
LP 30-300Hz (x1)
LP 600Hz-6kHz (x20)
Mindest-Querschnitte für Stromkabel bei
angegebener Leitungslänge inkl. Sicherung
Empfehlung ist Mini ANL/ANL Streifen-
sicherung.
Bei High Power immer den nächst größeren
Querschnitt verwenden.
Bitte verwenden Sie mindestens 1,5mm²
Lautsprecherleitung für Lautsprecher-
systeme und 2,5mm² für Subwoofer.
Als Zuleitung für das High Pegel Eingangs-
signal wird ein verdrilltes, 2x0,5mm² pro
Kanal empfohlen.
Min. section power supply cables for cable
length incl. Fuse.
Mini ANL/ANL Fuse is recommended.
For High Power use the next higher wire
gauge.
Please use at least 1.5 mm² speaker cable
for speaker systems and 2.5 mm² for
subwoofers.A twisted cable with 2x 0.5 mm²
per channel is recommended as the supply
cable for the high level input signal.
Kabellänge
cable lenth
Querschnitt
section
Sicherung
Fuse
1-2m 10mm² / 8 AWG 40A
2-4m 16mm² / 6 AWG 60A
4-6m 20mm² / 4 AWG 80A