Do you have a question about the EUCHNER MGB-L1 AP Series and is the answer not in the manual?
| Enclosure Material | Plastic |
|---|---|
| Protection Class | IP67 |
| Coding Level according to ISO 14119 | High |
| Enclosure Rating | IP67 |
| Operating Voltage | 24 VDC |
| Auxiliary Outputs | 1 x PNP |
| Housing Material | Plastic |
| Safety Category | 4 |
| Mechanical Life | 1 million operations |
| Electrical Life | 100, 000 cycles |
| Connection Type | M12 connector |
| Contact Configuration | 2 N/O (safety), 1 N/O (auxiliary) |
Explains the guard locking mechanism for the MGB-L1 version, actuated by spring force.
Describes the guard locking mechanism for the MGB-L2 version, actuated by solenoid force.
Explains the function and operation of the auxiliary release for manual guard locking release.
Details the emergency release feature, its installation, and operation for opening guards.
Covers the optional escape release for opening guards from the inside without tools.
Explains the requirements for fuse protection based on device and current consumption.
Guides users on reconfiguring the device settings using DIP switches.
Details the terminal assignments and descriptions for all connections and LEDs.
Guides the process of assigning a handle module to the locking module via teach-in.
Details the steps for performing a mechanical function test on the MGB system.
Outlines the procedure for conducting electrical function tests for the MGB system.
Provides step-by-step instructions for resetting errors and returning the system to normal operation.