17
2119167-06-10/20 (Translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L1…-AR.-… / MGB-L2…-AR.-… and MGB-L1…-AP.-… / MGB-L2…-AP.-…
EN
55,5
M4
250
182
D -1
D + 10,25
±1,25
D
(11,5) 55,5
Example without mounting plates:
Escape release
Handle module
Actuation axis Protective sleeve
(+4 mm per mounting plate)
(+4 mm per mounting plate)
1
Insert actuation axis. The snap ring A must be in contact with the escape release B.
2
Fit door handle.
3
Tighten xing screw to 2Nm and push in cap.
4
Fit protective sleeve.
1
3
2
4
A
B
Figure 7: Preparing escape release