EVCO S.p.A. | EV3 300 series | Instruction sheet ver. 1.0 | Code 1043300E103 | Page 1 of 2 | PT 50/17
EV3 300 series
Temperature modules for basic ovens
EN
ENGLISH
- user interface with push encoder or touch keys (according to the model).
- 230 VAC or 12 VAC/DC power supply (according to the model).
- regulation probe (J/K).
- multi-purpose input.
- relay output, 5 A res. @ 250 VAC or open collector, 12 VDC, 10 mA for SSR module
control (according to the model).
- alarm buzzer.
- on-off/PID control.
- hot or cold mode regulation.
- operation with programming key.
N.B.
- the push encoder is not provided.
- for models with a push encoder user interface, it is mandatory.
- models with a touch key user interface also operate with push encoder.
Purchasing code
User interface
Power supply
Output
EV3301J2 push encoder 12 VAC/DC relay, 5 A res.
EV3301J7 push encoder 230 VAC relay, 5 A res.
EV3301J7VR0
push encoder
230 VAC
open collector,
12 VDC, 10 mA
EV3311J2 touch keys 12 VAC/DC relay, 5 A res.
EV3311J7 touch keys 230 VAC relay, 5 A res.
EV3311J7VR0
touch keys
230 VAC
open collector,
12 VDC, 10 mA
1
MEASUREMENTS AND INSTALLATION
Measurements in mm (in); 39.5 (1 9/16) depth with fixed screw terminal blocks, 52.5 (2 1/16)
depth with plug-in screw terminal blocks.
To be fitted to a panel, snap-in brackets provided.
INSTALLATION PRECAUTIONS
- the thickness of the panel must be between 0.8 and 2.0 mm (1/32 and 1/16 in).
- ensure that the working conditions are within the limits stated in the TECHNICAL
SPECIFICATIONS section.
- do not install the device close to heat sources, equipment with a strong magnetic field,
in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations
or shocks.
- in compliance with safety regulations, the device must be installed properly to ensure
adequate protection from contact with electrical parts. All protective parts must be
fixed in such a way as to need the aid of a tool to remove them.
2
ELECTRICAL CONNECTION
N.B.
- use cables of an adequate section for the current running through them.
- ensure that the thermocouple is properly insulated from contact with metal parts or
use an already insulated thermocouple.
- if necessary, extend the thermocouple cable using a compensating cable.
- to reduce any electromagnetic interference locate the power cables as far away as
possible from the signal cables.
PRECAUTIONS FOR ELECTRICAL CONNECTION
- if using an electrical or pneumatic screwdriver, adjust the tightening torque.
- if the device is moved from a cold to a warm place, humidity may cause condensation
to form inside. Wait for about an hour before switching on the power.
- make sure that the supply voltage, electrical frequency and power are within the set
limits. See the section TECHNICAL SPECIFICATIONS.
- disconnect the power supply before carrying out any type of maintenance.
- do not use the device as a safety device.
- for repairs and for further information, contact the EVCO sales network.
3
FIRST-TIME USE
1. Carry out the installation following the instructions given in the section MEASUREMENTS
AND INSTALLATION.
2. Power up the device as set out in the section ELECTRICAL CONNECTION: an internal
test will start up.
The test normally takes a few seconds; when it is finished the display will switch off.
3. Configure the device as shown in the section Setting configuration parameters.
Recommended configuration parameters for first-time use:
PAR.
DEF.
PARAMETER
MIN... MAX.
SP 0 setpoint r1... r2
P0 2 type of probe
2 = J 3 = K
P2 0 temperature measurement unit 0 = °C 1 = °F
r5
1
hot or cold mode regulation
0 = cold mode
1 = hot mode
Then check that the remaining settings are appropriate; see the section CONFIGURA-
TION PARAMETERS.
4. Disconnect the device from the mains.
5. Make the electrical connection as shown in the section ELECTRICAL CONNECTION with-
out powering up the device.
6. If necessary, connect the push encoder.
7. Power up the device.
4
USER INTERFACE AND MAIN FUNCTIONS
4.1 Switching the device on/off
To switch on push encoder models:
1.
Press the encoder.
To switch off push encoder models:
1.
Press the encoder for 2 s.
To switch on touch key models:
1.
Touch the ON/STAND-BY key.
To switch off touch key models:
1.
Touch the ON/STAND-BY key for 2 s.
If the device is switched on, the display will show the P5 value ("regulation temperature" de-
fault); if the display shows an alarm code, see the section ALARMS.
LED
ON
OFF
FLASHING
OUT1
regulator active
-
- regulator protection active
- setpoint being set
alarm active
-
-
OUT2
unused
-
-
SEC
unused
-
-
device switched off
device switched on
device being switched off
°C/°F
temperature display
-
-
%
unused
-
-
MIN
unused
-
-
If Loc = 1 and 30 s have elapsed without the keys being pressed, the display will show the
"Loc" label and the keypad will lock automatically.
4.2 Unlocking the keypad
Touch a key for 1 s: the display will show the label “UnL”.
4.3 Setting the setpoint
For push encoder models:
1.
Rotate the encoder.
2.
Rotate the encoder within 15 s to set the value within the limits
r1 and r2 (default "0... 350”).
3.
Press the encoder.
4.
Take no action for 15 seconds to exit the procedure in advance: the device will not
save the entered value.
For touch key models:
- check that the keypad is not locked.
1.
Touch the SET key.
2.
Touch the UP or DOWN keys within 15s to set the value within
the limits r1 and r2 (default "0... 350”).
3.
Touch the SET key.
4.
Touch the ON/STANDBY key (or take no action for 15 s) to exit
the procedure in advance: the device will not save the entered
value.
4.4 Silencing the buzzer
For push encoder models:
- rotate or press the encoder.
For touch key models:
- touch a key.
5
OPERATION WITH ON-OFF CONTROL
Cold mode regulation (r5 = 0).
Hot mode regulation (r5 = 1).
6
SETTINGS
6.1 Setting configuration parameters
N.B.
Changing parameter P2 from °C to °F (and vice versa) causes the value of the pa-
rameters whose unit of measurement is ° C or ° F to be changed automatically.
For push encoder models:
- make sure that the device is switched off.
1.
Press the encoder for 4 s: the display will show the label “PA”.
2.
Press the encoder.
3.
Rotate the encoder within 15 s to set the PAS value (default
-19”).
4.
Press the encoder (or take no action for 15 s): the display will
show the label “SP”.
5.
Rotate the encoder to select a parameter.
6.
Press the encoder.
7.
Rotate the encoder within 15 s to set the value.
8.
Press the encoder (or take no action for 15 s).
9.
Press the encoder for 4 s (or take no action for 60 s) to exit the
procedure.
For touch key models:
- make sure that the device is switched off.
1.
Touch the SET key for 4 s: the display will show the label “PA”.
2.
Touch the SET key.
3.
Touch the UP or DOWN key within 15s to set the PAS value (de-
fault "-19").
4.
Touch the SET key (or take no action for 15s): the display will
show the label “SP”.
5.
Touch the UP or DOWN key to select a parameter.
6.
Touch the SET key.
7.
Touch the UP or DOWN key within 15s to set the value.
8.
Touch the SET key (or take no action for 15s).
9.
Touch the SET key for 4s (or take no action for 60s) to exit the
procedure.
6.2 Restoring factory settings (default) and saving customised settings
N.B.
- Check that the factory settings are appropriate; see the section CONFIGURATION
PARAMETERS.
- Saving customised settings overwrites the factory settings.
For push encoder models:
- make sure that the device is switched off.
1.
Press the encoder for 4 s: the display will show the label “PA”.
2.
Press the encoder.
3.
Rotate the encoder within 15 s to set the value.
VAL.
DESCRIPTION
149 value for restoring the factory information (default)
161 value for saving customised settings
4.
Press the encoder (or take no action for 15 s): the display will
show the label dEF (for setting the 149 value) or the label
MAP” (for setting the161” value).
5.
Press the encoder.
6.
Rotate the encoder within 15 s to set the value “4”.
7.
Press the encoder (or take no action for 15 s): the display will
show - - -flashing for 4 s, after which the device will exit the
procedure.
8. Disconnect the device from the power supply.
9.
Press the encoder for 2s before action 6 to exit the procedure be-
forehand.
For touch key models:
- make sure that the device is switched off.
1.
Touch the SET key for 4 s: the display will show the label “PA”.
2.
Touch the SET key.
3.
Touch the UP or DOWN key within 15s to set the value.
VAL.
DESCRIPTION
149 value for restoring the factory information (default)
161 value for saving customised settings
4.
Touch the SET key (or take no action for 15 s): the display will
show the label dEF (for setting the 149 value) or the label
MAP” (for setting the161” value).
5.
Touch the SET key.
6.
Touch the UP or DOWN key within 15s to set "4".
7.
Touch the SET key (or take no action for 15 s): the display will
show “- - -“ flashing for 4 s, after which the device will exit the
procedure.
8. Disconnect the device from the power supply.
9.
Touch the SET key for 2s before action 6 to exit the procedure
beforehand.
Question and Answer IconNeed help?

Do you have a question about the Evco EV3 300 Series and is the answer not in the manual?

Summary

Electrical Connection Precautions

First-Time Device Use

User Interface and Main Functions

Switching Device On and Off

Instructions for turning the device on and off using push encoder or touch keys.

Measurements and Installation

Installation Precautions

Electrical Connection

On-Off Control Operation

Setting Configuration Parameters

Restoring Factory Settings

Overview

This document describes the EV3 300 series, a range of function controllers designed for various applications, primarily focusing on temperature regulation.

Function Description

The EV3 300 series controllers are built-in electronic devices primarily used for temperature regulation. They feature a 3-digit LED display with function icons and a built-in push encoder for interaction. The controllers support both hot and cold mode regulation and can be configured for various probe types (J or K thermocouples). They include a single relay output (K1) for controlling external devices and a multi-purpose digital input. The device also incorporates alarm functionalities for temperature deviations and probe failures, with configurable thresholds and delays.

Important Technical Specifications

General:

  • Purpose: Function controller
  • Construction: Built-in electronic device, black, self-extinguishing
  • Category of heat and fire resistance: D
  • Mounting: To be fitted to a panel, with snap-in brackets
  • Degree of protection (front): IP65
  • Operating Temperature: 0 to 60 °C (32 to 140 °F)
  • Storage Temperature: -25 to 70 °C (-13 to 158 °F)
  • Operating Humidity: 10 to 90% relative humidity, without condensate
  • Pollution Status: 2
  • Compliance: RoHS 2011/65/EC, WEEE 2012/19/EU, EMC 2014/30/EU, LVD 2014/35/EU, REACH (EC) Regulation no. 1907/2006

Dimensions:

  • Fixed screw terminal blocks: 75.0 x 33.0 x 39.5 mm (2 15/16 x 1 5/16 x 1 9/16 in)
  • Plug-in screw terminal blocks: 75.0 x 33.0 x 52.5 mm (2 15/16 x 1 5/16 x 2 1/16 in)

Power Supply:

  • EV3... J7: 230 VAC (+10%-15%), 50/60 Hz (±3 Hz), max. 2 VA
  • EV3... J2: 12 VAC/DC (+10%-15%), 50/60 Hz (±3 Hz), max. 5 VA/3W
  • Rated Impulse-Withstand Voltage: 4 KV
  • Over-voltage Category: III
  • Software Class and Structure: A

Inputs:

  • Analog Inputs: 1 for J/K thermocouples (regulation probe)
    • J thermocouples: Measurement field 0 to 700 °C (32 to 999 °F), Resolution 1 °C (1 °F)
    • K thermocouples: Measurement field 0 to 999 °C (32 to 999 °F), Resolution 1 °C (1 °F)
  • Digital Inputs: 1 dry contact (multi-purpose), 5 VDC, 1.5 mA

Outputs:

  • K1 Relay: SPST, 5 A res. @ 250 VAC
  • Open Collector: 6... 14 VDC, 10 mA (Type 1 or Type 2 Actions)

Connection Cables (Maximum Permitted Length):

  • Power Supply: 10 m (32.8 ft)
  • Digital Inputs: 10 m (32.8 ft)
  • Analog Inputs: 10 m (32.8 ft)
  • Digital Outputs: 10 m (32.8 ft)
  • Wire Size: Up to 2.5 mm²

Usage Features

The EV3 300 series offers a user-friendly interface with a push encoder for navigation and parameter setting.

Basic Operations:

  • Switching the device on/off: Press and hold the SET key for 4 seconds.
  • Displaying the setpoint: Press the SET key once.
  • Modifying the setpoint: Press SET, then use UP/DOWN to adjust, and SET again to confirm.
  • Unlocking the keypad: Press and hold SET for 4 seconds, then use UP/DOWN to enter the password (default 12), and SET to confirm.
  • Accessing parameters: Press and hold SET for 4 seconds, then use UP/DOWN to enter the password (default 12), and SET to confirm. Navigate parameters with UP/DOWN, modify with SET, adjust with UP/DOWN, and confirm with SET.

Regulation Features:

  • Setpoint (SP): Configurable range from r1 to r2.
  • Regulation Probe Offset (CA1): Adjusts the probe reading from -25 to 25 °C/°F.
  • Probe Type (PO): Selects between J (2) and K (3) thermocouples.
  • Temperature Measurement Unit (P2): Selects between °C (0) and °F (1).
  • Hot or Cold Mode Regulation (r5): Configurable for cold (0) or hot (1) mode.
  • Setpoint Differential (r0): Defines the hysteresis for regulation.
  • PID Control: Parameters like proportional band (r14), integral action time (r15), derivative action time (r16), and regulator cycle time (r17) can be configured for precise control.

Alarm Features:

  • Temperature Alarm Threshold (A1): Sets the temperature deviation for alarms.
  • Temperature Alarm Type (A2): Configurable for absolute low, absolute high, low relative to setpoint, or high relative to setpoint alarms.
  • Alarm Delays (A3, A7, A8): Delays for alarm activation, after setpoint modification, and after silencing.
  • Temperature Alarm Switch Off Differential (A11): Hysteresis for alarm deactivation.

Digital Input Functionality (i5):

  • The multi-purpose digital input can be configured for various functions: disabled, alarm iA, alarm iA + regulator off, switches device on/off, or modifies setpoint.
  • Activation (i6): Configurable for activation with contact closed or contact open.

Security Features:

  • Keypad Lock (Loc): Enables or disables keypad lock.
  • Password (PAS): Default -19 (for parameter access).

Maintenance Features

Alarms and Troubleshooting: The device provides alarm codes to indicate specific issues:

  • Pr1 (Regulation Probe Alarm): Indicates a problem with the regulation probe.
    • Reset: Automatic.
    • To Correct: Check PO parameter, probe integrity, and electrical connection.
  • AL (Temperature Alarm): Indicates a temperature alarm.
    • Reset: Automatic.
    • To Correct: Check A1 and A2 parameters.
  • iA (Multi-purpose Input Alarm): Indicates an alarm from the multi-purpose input.
    • Reset: Automatic.
    • To Correct: Check i5 and i6 parameters.

Electrical Connection:

  • All connections must be made with the device switched off.
  • Use cables with a cross-section of 0.5 to 2.5 mm² (20 to 14 AWG).
  • For power supply, use an adequately insulated thermocouple.
  • Avoid running power supply cables and signal cables in the same conduit to prevent electromagnetic interference. If necessary, use shielded cables for signal lines.

Disposal: The device must be disposed of according to local regulations governing the collection of electrical and electronic equipment.

Evco EV3 300 Series Specifications

General IconGeneral
BrandEvco
ModelEV3 300 Series
CategoryControl Unit
LanguageEnglish

Related product manuals