EasyManua.ls Logo

Event 2030 - low frequency amplifier; high frequency amplifier

Event 2030
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
specifi cations
low frequency amplifi er
high frequency amplifi er
Frequency Response
20Hz - 40kHz (± 0.25dB)
bandwidth limited
Operating Band Pass
20Hz - 400Hz
Total Harmonic Distortion
0.02% @ 120 watts into 4ohm load
Long Term Power @ 4 Ohms*
80 watts
Power @ 4 Ohms**
120 watts
Output T
opology
Class AB with proprietary soft
clipping topology
Cooling
Convection - Aluminium heat sink
Frequency Response
20Hz - 40kHz (± 0.25dB)
(bandwidth limited)
Operating Band Pass
400Hz - 30kHz
Total Harmonic Distortion
0.02% @ 120 watts into 4ohm load
Long Term Power @ 6 Ohms*
80 watts
Power @ 6 Ohms**
120 watts
Output T
opology
Class AB with proprietary soft
clipping technology
Cooling
Convection - Aluminium heat sink
* Both high frequency and low frequency were measured independently for this specifi cation.
Long term power was measured using 1kHz sine wave signal.
** Burst power was measured using a 1kHz burst tone waveform where the burst portion contains 4 cycles
(on) and the low level signal contains 200 cycles (off). This test signal succinctly represents the strain and
demands placed on the amplifi er by music content containing high transients.
709-950-1-1_2030_usermanual.indd 16709-950-1-1_2030_usermanual.indd 16 12/03/2012 12:06:14 PM12/03/2012 12:06:14 PM