EasyManua.ls Logo

Everbilt SBA033BC User Manual

Everbilt SBA033BC
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
210*55mm
• Connect the pump DIRECTLY to a properly grounded, 115V GFCI outlet and
never use an extension cord to power this pump
• Pull plug before servicing this pump
• This pump has not been tested or approved for use in swimming pools or in
salt-water marine areas
• Do not pump flammable or explosive liquids, pump water only with this pump
• To reduce risk of electrical shock, fully read, follow and save the operating and
installation instructions before attempting to install or operate this pump
• Do not run this pump dry
NOTICE: Do not handle pump with wet hands or when standing on a wet surface,
or in water
• Conecte la bomba DIRECTAMENTE a una toma de tierra, nunca utilice un cable de
extensión para proporcionar alimentación a la bomba
• Desconecte la bomba antes de cualquier clase de mantenimiento
• Esta bomba no se ha puesto a prueba y no ha sido aprobada para uso en piscinas
o en áreas de agua salada
• No bombee líquidos inflamables o explosivos, bombee solamente agua con esta
bomba
• Para reducir el riesgo de descarga eléctrica, lea totalmente, siga y guarde las
instrucciones de uso e instalación antes de intentar instalar o utilizar la bomba
• No haga funcionar esta bomba en seco
AVISO: No maneje la bomba con las manos mojadas o estando en agua o en la
superficie mojada
MADE IN CHINA HECHO EN CHINA
ADVERTENCIA
WARNING
cord tag
70*17mm
logo
name plate
75*50mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Submersible Sump Pump
Bomba De Sumidero Sumergible
115V 60Hz 1/4HP 6.4Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1001 093 932
Model SBA025BC
name plate
75*50mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Submersible Sump Pump
Bomba De Sumidero Sumergible
115V 60Hz 1/3HP 7.6Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1001 093 909
Model SBA033BC
name plate
75*50mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Submersible Sump Pump
Bomba De Sumidero Sumergible
115V 60Hz 1/3HP 7.6Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1000 000 000
Model SBA033V1
name plate
75*50mm
Serial No./Serial No.: 000000
Date Code/Código de Fecha: 1439
Submersible Sump Pump
Bomba De Sumidero Sumergible
115V 60Hz 1/2HP 6.5Amps
THERMALLY PROTECTED
PROTECCIÓN TÉRMICA
SKU 1001 093 925
Model SBA050BC
Question and Answer IconNeed help?

Do you have a question about the Everbilt SBA033BC and is the answer not in the manual?

Everbilt SBA033BC Specifications

General IconGeneral
Model NumberSBA033BC
Horsepower1/3 HP
Max Head/Lift Height25 ft
Cord Length10 ft
Automatic OperationYes
Thermal ProtectionYes
Power SourceElectric

Summary

Warranty

Warranty Terms and Conditions

Details the manufacturer's warranty, coverage, exclusions, and claims process for the sump pump.

Pre-Installation Guide

Application and Limitations

Specifies the intended uses, restrictions, and warnings for the submersible sump pump.

Tools and Materials Required

Lists the necessary tools and materials for proper installation, including items not supplied.

Package Contents

Identifies all components included in the product packaging.

Product Specifications

Provides essential technical details like voltage, temperature range, discharge size, and sump basin requirements.

Installation Instructions

Pump Operation Guide

Care and Cleaning Procedures

Troubleshooting Common Issues

Quick Start Guide

Tools Needed

Lists the essential tools required for initial setup and installation of the sump pump.

Materials Needed

Lists the necessary components and supplies not included with the sump pump.

Sump Pit Requirements

Details the specifications for the sump pit, including diameter, depth, and surface material.

Installing Discharge Plumbing

Provides instructions for connecting the discharge pipe, check valve, and anti-airlock hole.

Inserting the Pump

Guides the user on placing the pump correctly into the sump pit, ensuring switch clearance.

Completing Plumbing and Power Connection

Covers the final steps for plumbing, including glue curing time and plugging into a GFCI outlet.

Verifying Pump Operation

Explains how to test the pump's functionality after installation by filling the sump and observing cycles.