6 Installation Instructions
4 Technical data
4.1 DC input data
Type TL 2100 TL 3200 TL 4600 TL 5400
Max. PV-generator power [W] 2100 3200 4600 5400
Max. DC Voltage [V] 580 580 680 680
MPPT voltage range [V] 125 - 530 125 - 530 125 - 550 125 - 550
Turn off DC Voltage [V] 125 125 125 125
Max. DC current [A] 18 20 20 25
Nominal DC current [A] 16.2 18 18 22.5
Number of DC connection 1 1 2 2
Number of MPP trackers 1 1 1 2
DC-connection MC IV-connector
Turn on power [W] 10
4.2 Output data
Type TL 2100 TL 3200 TL 4600 TL 5400
AC connector Spring-clamp tech
Power connection Single phase
Rated AC power [W] 1800 2800 4000 4600
Max. AC Power [W] 1980 3080 4400 5060
Grid voltage range 187-264 V / 207-264
Grid frequency range 47.5-50.2 Hz / 47-50.5Hz
Rated current [A] 7.8 12.2 17.4 20.0
Max. current [A] 9.9 / 9.57 15.4 / 14.9 22 / 21.3 25.3 / 24.4
Power factor 0.99 0.99 0.99 0.99
Harmonic distortion (THD) at
rated output
<2% <2% <2% <2%
Power consumption at night [W] <0.2 <0.2 <0.2 <0.2
Power consumption at standby [W] 6 6 6 6