3-3 Other Function Settings (P4 oth)
Enter other funcfion settings”P4 oth” and press key to enter sub-menue setting. Press
Key to select ON or OFF in Animal mode and Auto. average unit weight. After seleting,
press key to save the setting or press key to exit without saving. After all settings
finished, press key to back to weighing mode.
Animal mode: Use when weighing animals that are in motion. The weight value can be
held for maximum weight or when the weight is stable depending on the hold function
setting.
Average unit weight: If the weight of the objects on platter > the previous sampling
number more than 5 pcs, and also < 200% the previous sampling number, the scale will
automatically adjust the unit weight.
Continuous tare: If this function off, it only can be tare for once. It can not be tare until
tare cancel; If this function on, ii can be tare continuously except gross weight >
capacity.
Default settings are marked by *
Press key to select ON or OFF*.
Press key to save the setting.
If it sets ON, in weighing mode, press
+ key to call up Hold mode.
Tare range setting: Press key
to adjust value. Press or
key to move cursor. Press key
to save the setting