Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at U.S.A:1-800-913-8999, 8 a.m.-5 p.m., PST, Monday-Friday.
This instruction manual contains important information necessary for the
proper assembly and safe use of the appliance.
Read and follow all warnings and instructions before assembling and
using the appliance.
Keep this manual for future reference.
FOR OUTDOOR USE ONLY
720-0789H PARA EXTERIOR SÓLAMENTE
POUR USAGE EXTÉRIEUR SEULEMENT
SERIAL # ____________________ MFG. DATE _____________________ PURCHASE DATE: _____________________
NÚM. DE SERIE ______________ FECHA DE MANUFACTURA ______________ FECHA DE COMPRA ______________
NUMÉRO DE SÉRIE _______________ DATE DE FABRICATION _______________ DATE D'ACHAT _______________
19000789A1
VSN: XG19-101-002-02

Questions and Answers

  • R
    riveracoreyAug 6, 2025
    How to fix EXPERT GRILL XG19-101-002-02 that will not light immediately?
    • J
      johnsoncraigAug 6, 2025
      If your EXPERT GRILL Grill won't light immediately, ensure you have a spark while lighting the burner. Check the battery installation and wire connection to the electrode assembly. Clean the wire(s) and/or electrode with rubbing alcohol and a clean swab, then wipe with a clean cloth. Check if other burners operate; if so, inspect the gas orifice on the malfunctioning burner for any obstruction.
  • D
    diazsaraAug 10, 2025
    What to do if the rotisserie burner on my EXPERT GRILL Grill won't light?
    • E
      Eric MillerAug 10, 2025
      If the rotisserie burner on your EXPERT GRILL Grill won't light when the igniter button is pushed, check for debris blocking the electrode and ensure there is a spark jumping to the burner from the electrode. If there's no spark, check the battery inside the igniter box by turning it counterclockwise to open. If the infrared back burner doesn't light with a match, ensure the gas is on.
  • M
    Mikayla PrinceAug 14, 2025
    What to do if my EXPERT GRILL XG19-101-002-02 Grill only heats to 200-300°F?
    • J
      johnrodriguezAug 14, 2025
      To reset the safety device on your EXPERT GRILL Grill, which restricts gas flow, turn off all burners and close the LP tank valve. Disconnect the regulator from the LP tank, wait one minute, then reconnect it. Slowly open the LP tank valve fully. Light all burners and observe the temperature. Also, check for a bent or kinked fuel hose, dust in the grill area, and clean the burner and orifices. Inspect for spiders and insects.
  • J
    Jennifer ReeseAug 19, 2025
    Why is the regulator on my EXPERT GRILL Grill making noise?
    • B
      bboydSep 12, 2025
      If the regulator on your EXPERT GRILL Grill is making noise, ensure the vent hole on the regulator is not obstructed. Clear the hole, close the gas control valves, wait ten minutes, and restart. Check your flames for proper performance; if the flames are not correct, replace the regulator. The noise could be due to a plugged vent hose or a faulty regulator.
  • A
    Allison PriceAug 23, 2025
    Why does my EXPERT GRILL XG19-101-002-02 Grill take a long time to preheat?
    • N
      Nicole WagnerAug 23, 2025
      Normal preheating of your EXPERT GRILL Grill to 500-600°F takes about 10-15 minutes. Cold weather and wind may affect your preheat time. Also, volcanic rock or briquettes can increase the preheat time and maximum temperature.
  • K
    Kathleen HollandAug 27, 2025
    Why won't the rotisserie motor on my EXPERT GRILL Grill turn?
    • J
      Jeremy RushAug 27, 2025
      If the rotisserie motor on your EXPERT GRILL Grill will not turn, ensure it's connected to a properly grounded power supply and the on/off switch is in the on position. Also, make sure the spit is fully inserted into the rotisserie motor, the load does not exceed 40 pounds, and there is no encumbrance or drag.
  • D
    dawnsimpsonAug 31, 2025
    Why are the burner flames on my EXPERT GRILL Grill not light blue?
    • T
      Timothy HessAug 31, 2025
      Burner adjustment may be required. The grill may be in a windy location. Too much or not enough air for the flame. Elevation is the principal cause, however cold weather can affect the mixture.

Summary

Safety Instruction

LP-Gas Supply System

Proper Placement And Clearance Of Grill

Specifies necessary clearances and safe locations for grill setup and use.

SAFETY PRACTICES TO AVOID PERSONAL INJURY

Gas Hook-Up

L.P. TANK REQUIREMENT

Specifies the necessary specifications and types of LP gas tanks for safe use.

Leak Testing

Operating Instructions

Lighting Instructions

Step-by-step guide on how to safely light the grill burners.

Component Identification

Care and Maintenance

Troubleshooting

Grill Cooking Chart

EXPERT GRILL XG19-101-002-02 Specifications

General IconGeneral
BrandEXPERT GRILL
ModelXG19-101-002-02
CategoryGrill
LanguageEnglish

Related product manuals