EasyManua.ls Logo

Explore Scientific WSX1001 - Console Communication and Time Specs; Console Wi-Fi Communication Specs; Wireless Sensor Communication Specs; Time Related Function Specs

Explore Scientific WSX1001
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Time synchronize method Through Internet time server to synchronize the UTC
Weekday languages EN / DE / FR / ES / IT / NL / RU
Time Zone +13 ~ -12 hour
DST ON / OFF
Barometer Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Barometer unit hPa, inHg and mmHg
Measuring range 540 ~ 1100hPa (relative setting range 930 ~ 1050hPa)
Accuracy
(700 ~ 1100hPa ± 5hPa) / (540 ~ 696hPa ± 8hPa)
(20.67 ~ 32.48inHg ± 0.15inHg) / (15.95 ~ 20.55inHg ±
0.24inHg)
(525 ~ 825mmHg ± 3.8mmHg) / (405 ~ 522mmHg ± 6mmHg)
Typical at 25°C (77°F)
Resolution 1hPa / 0.01inHg / 0.1mmHg
Weather forecast
Sunny / Clear, Slightly Cloudy, Cloudy, Rainy, Rainy / Stormy
and Snowy
Display modes Current
Memory modes Historical data of past 24 hours, daily Max / Min
Alarm Pressure change alert
Indoor / Outdoor Temperature Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Temperature unit °C and °F
Display range
Indoor:-40 ~ 70°C(-40 ~ 158°F), Outdoor:-40 ~ 80(-40 ~
176°F)
Indoor Accuracy
<0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Outdoor Accuracy
60.1 ~ 80°C ± 0.8°C (140.2 ~ 176°F ± 1.4°F)
5.1 ~ 60°C ± 0.4°C (41.2 ~ 140°F ± 0.7°F)
-19.9 ~ 5°C ± 1°C (-3.8 ~ 41°F ± 1.8°F)
-40 ~ -20°C ± 1.5°C (-40 ~ -4°F ± 2.7°F)
Resolution °C / °F (1 decimal place)
Display modes Current
Memory modes Historical data of past 24 hours, daily Max / Min
Alarm Hi / Lo temperature alert
Indoor / Outdoor Humidity Display & Function Specication
Note: The following details are listed as they are displayed or operate on the console.
Humidity unit %
Display range 1 ~ 99%
Indoor Accuracy
20~39% or 71~90% RH ±8%RH @ 25°C (77°F)
40~70% RH ±5%RH @ 25°C (77°F)
Outdoor Accuracy
1 ~ 20% RH ± 6.5% RH @ 25°C (77°F)
21 ~ 80% RH ± 3.5% RH @ 25°C (77°F)
81 ~ 99% RH ± 6.5% RH @ 25°C (77°F)
Resolution 1%
Display modes Current
Memory modes Historical data of past 24 hours, Max / Min
Alarm Hi / Lo Humidity Alert