EasyManua.ls Logo

Extech Instruments 380803

Extech Instruments 380803
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
380801-380803-EN v7.2 07/13
8
Using Two Power Analyzers
Measure W
RS
and W
TS
(RST phases must be correctly identified)
1. Connect the R-phase of the power source to the black terminal of the input voltage of
power analyzer 1.
2. Connect the S-phase of the power source to the red terminal of the input voltage of
power analyzer 1.
3. Plug the R-phase of the device to be tested to the black terminal of the output load of
power analyzer 1. Do not short the R-phase of the load to the R-phase of the input
power source.
4. Record the reading of W
RS
displayed on the ‘W’ LCD of power analyzer 1.
5. Connect the T-phase of the power source to the black terminal of the input voltage of
power analyzer 2.
6. Connect the S-phase of the power source to the red terminal of the input voltage of
power analyzer 2.
7. Plug the T-phase of the device to be tested to the black terminal of the output load. Do
not short the T-phase of the device to be tested to the T-phase of the input power
source.
8. Record the reading of W
TS
displayed on the Watt LCD of power analyzer 2.

Related product manuals