CHAPTER 31
PAGE 10
EXT
RA - FLUGZEUGBAU GmbH
SERVICE MANUAL EXTRA 200
PAGE DATE: 1. July 1996
31-50-00 CENTRAL WARNING SYSTEMS
31-50-01 Stall Warning System
The EXTRA 200 is equipped with a stall warning system as
standard. This system is designed to warn the pilot by an
audible alarm horn, which is fitted in the back of the front
seat. The stall warning switch is located at the RH wing
leading edge. The electrical circuit of the stall warner is
independently secured with an automatic 1 ampere circuit
breaker in the rear instrument panel.
The stall warning switch has been adjusted at the factory
after a test flight. It is set to trigger the warning approx. 5-
10 knots prior to stalling in normal flight. The switch should
require no adjustment in normal service.