26
Air circulation ducts
To ensure correct operation, it is necessary to create air intakes at the top of the fireplace.
These can be made in the sides of the hood or on the front.
The following measurements must be respected:
Air intakes made on both sides of the fireplace: Minimum measurement required 200 cm
2
per side.
Air intake made on the front of the fireplace: Minimum measurement required 400 cm
2
per
side.
For fresh air intake, it is very important to make one or more holes on the lower or side part of the
facing.
N.B. This ventilation system is completely independent from the combustion air
intake!!
These air circulation points must have a minimum area of 750 cm².