USER PARAMETERS
33
Chapter 10
Let’s suppose that the weekly programmer function is to be used and 3 time periods are to be used in the
following way:
1st time span: from 08:00 to 12:00 every day of the week excluding Saturday and Sunday
2nd time span: from 15:00 to 22:00 only Saturday and Sunday
3rd time span: not used
Let’s set the data.
Parameter 0 (D2=UT 0( ashing); D1=ON]
Use buttons 2 and 3 to activate the weekly programmer by setting the value on display D2 at ON.
Parameter 1 (D2=UT 1( ashing); D1=E.g. “08:00:00”]
Use buttons 2 or 3 to set “08:00”, which corresponds to the switch-on time of the 1st time span. To con rm
and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 2 (D2=UT 2( ashing); D1=E.g. “12:00:00”]
Use buttons 2 or 3 to set “12:00:00”, which corresponds to the switch-o time of the 1st time span. To
con rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 3 (D2=UT 3( ashing); D1= “OFF 1”]
Activate the rst time span for every day of the week except Saturday and Sunday. To do this use keys 2
and 3 in the following way:
a. key 3 - scroll the various days
b. key 2 - enable/disable (ON/OFF) the 1st time span for that day
Example:
Day Initial value Function key 2 Final value Function key 3
MONDAY OFF 1 OFF 1 D ON 1 and vice versa ON 1(time span active) Go to next day
TUESDAY OFF 2 OFF 2 D ON 2 and vice versa ON 2(time span active) Go to next day
WEDNESDAY OFF 3 OFF 3 D ON 3 and vice versa ON 3(time span active) Go to next day
THURSDAY OFF 4 OFF 4 D ON 4 and vice versa ON 4(time span active) Go to next day
FRIDAY OFF 5 OFF 5 D ON 5 and vice versa ON 5(time span active) Go to next day
SATURDAY OFF 6 OFF 6 D ON 6 and vice versa OFF 6(time deactivated) Go to next day
SUNDAY OFF 7 OFF 7 D ON 7 and vice versa OFF 7(time deactivated) Go to next day
To con rm and continue programming, press button 5.
Press button 4 to go back to the previous parameter.
Parameter 4 (D2=UT 4( ashing); D1= “00”]
N.B. This parameter is reserved for the after-sales service and must not be modi ed.
Parameter 5 (D2=UT 5( ashing); D1=E.g. “15:00:00”]
Use buttons 2 or 3 to set “15:00”, which corresponds to the switch-on time of the 2nd time span. To con rm
and continue programming, press button 5.
Press button 4 to go back to the previous parameter.