EasyManua.ls Logo

Extreme Networks Summit X450e-48p - Page 146

Extreme Networks Summit X450e-48p
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Confidential and proprietary information of Extreme Networks. © 2011 Extreme Networks, Inc.
All rights reserved. DRAFT. October 20, 2011
Summit Family Switches Hardware Installation Guide
365
International Safety of ITE CB Report & Certificate per IEC 60950-1 2nd Ed. + National Differences
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards EN 55022:2006+A1:2007 Class A
EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8-2006 (Harmonics)
EN 61000-3-3 2008 (Flicker)
ETSI EN 300 386 v1.4.1, 2008-04 (EMC Telecommunications)
2004/108/EC EMC Directive
International EMC certifications CISPR 22: 2006 Ed 5.2, Class A (International Emissions)
CISPR 24:A2:2003 Class A (International Immunity)
IEC 61000-4-2:2008/EN 61000-4-2:2009
Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A
IEC 61000-4-3:2008/EN 61000-4-3:2006+A1:2008
Radiated Immunity 10V/m, Criteria A
IEC 61000-4-4:2004 am1 ed.2./EN 61000-4-4:2004/A1:2010
Transient Burst, 1 kV, Criteria A
IEC 61000-4-5:2005 /EN 61000-4-5:2006
Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A
IEC 61000-4-6:2008/EN 61000-4-6:2009
Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A
EC/EN 61000-4-11:2004
Power Dips & Interruptions, >30%, 25 periods, Criteria C
Country-specific VCCI Class A (Japan Emissions)
ACMA (C-Tick) (Australia Emissions)
CCC Mark
KCC Mark, EMC Approval (Korea)
Telecom Standards
ETSI EN 300 386:2001 (EMC Telecommunications)
ETSI EN 300 019 (Environmental for Telecommunications)
IEEE 802.3 Media Access
Standards
IEEE 802.3ab 1000BASE-T
Environmental Data
Environmental standards EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
EN/ETSI 300 753 (1997-10) - Acoustic Noise
ASTM D3580 Random Vibration Unpackaged 1.5 G
Operating conditions Temperature range:
Summit X460-24t, X460-48t, X460-24x, and X460-48x
C to 45° C (32° F to 113° F)
Summit X460-24p, X460-48p
C to 40° C (32° F to 104° F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 3,000 meters (9,850 feet)
Shock (half sine): 30 m/s
2
(3 G), 11 ms, 60 shocks
Random vibration: 3 to 500 Hz at 1.5 G rms
Table 67: Summit X440 Series Switch Technical Specifications (Continued)