Operating Manual
6
Warning! For ATEX/IECEx GROUP I applications ONLY the rated ambient
temperature range of the equipment is from 0
o
C to 60
o
C.
Warning! For Class 1 Division 1 applications ONLY the rated ambient temperature
range of the equipment is from -20
o
C to 55
o
C/50
o
C dependent on the
cells used (see Table 1).
Warning! If any damage to the iCAM50x is found which may invalidate the required
safety minimum IP rating (IP54 for group I applications), (IP20 for group
II and class 1 division 1 applications), the iCAM50x shall be removed
from the hazardous area.
Important Any repairs or replacement of parts MUST be performed by the
manufacturer or its nominated sub-contractor or agent.
Important The iCAM50x contains no user serviceable parts. The main part of the
enclosure must not be opened under any circumstances.
1.3.1.2 Notes specific to iCAM501U units dated before 18
th
July 2013
Warning! For ATEX/IECEx GROUP I and GROUP II applications, ONLY Duracell
Plus MN1500 or Duracell Procell MN1500 cells may be used with the
iCAM501U (see Table 1).
Warning! For Class 1 Division I applications, ONLY Duracell Plus MN1500, Duracell
Procell MN1500, Duracell Procell PC1500 or Energizer E91 cells may be
used with the iCAM501U (see Table 1).
Warning! For Class1 Division 1 applications NOTE THE DIFFERENT
TEMPERATURE CLASSIFICATION of T4 at 55
o
C when Duracell MN1500/
Duracell Procell MN1500 cells are used (see Table 1).
Warning! For Class1 Division 1 applications NOTE THE DIFFERENT
TEMPERATURE CLASSIFICATION of T3C at 50
o
C when Duracell
PC1500/Energizer E91 are used (see Table 1).