Page 21
May, 2006
415 L LS Operator And
455 D Control Panel Installation Manual
THE 455 D CONTROL PANEL INSTALLATION INSTRUCTIONS
FAIL SAFE:
If this function is activated, it en-
ables a function test of the photo-
cells before any gate movement.
If the test fails (photocells not
serviceable), the gate does not
start the movement.
Y = Enable
No = Disabled
P
RE FLASHING (5S):
Activates the flashing lamp for 5s
before start of movement.
Y = Enable
No = Disabled
E
LECTRIC LOCK ON LEAF 2:
For using the electric lock on leaf 2
instead of on leaf 1.
Y = Enable
No = Disabled
Display Function Default
I
NDICATOR-LICHT:
If 0 is selected, the output func-
tions as a standard indicator-light
(lighted at opening and pause,
flashing at closing, and off when
gate closed). Different figures
correspond to timed activation of
the output, which can be used (via
a relay) to power a courtesy lamp.
Time can be adjusted from 0 to
59s in 1s increments, and from
1.0 to 4.1 min. in 10s steps.
0 = Standard Indicator-Light
From 1 to 4.1 = Timed Output
C
LOSING PHOTOCELLS REVERSE AT
RELEASE: Enable this function if
you want the closing photocells to
stop the gate movement and re-
verse it after the beam is cleared.
Default setting is immediate re-
verse.
Y = Enable
No = Disabled
A.D.M.A.P. F
UNCTION:
If this function is enabled, the
safety devices operate in compli-
ance with French standard NFP
25/362.
Y = Enable
No = Disabled
ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, press the “F” key
and, as you hold it down, press the “+” key:
If you release the “+”, the display indicates the name
of the first function.
If you release the “F” key, too, the display shows the
value of the function that can be modified with keys
“+” and “—.
If you press the “F” key (and hold it down), the dis-
play shows the name of the next function, and if
you release it, the value that can be modified with
keys “+” and “—”.
When you reach the last function, press the “F” key
to exit the program, and the display resumes show-
ing the status of the inputs.
The table on page 21 and 22 shows the sequence of
functions accessible in
ADVANCED PROGRAMMING.
ADVANCED PROGRAMMING
+
Display Function Default
M
AXIMUM TORQUE AT INITIAL
T
HRUST: The motors operate
at maximum torque (ignoring
the torque setting) at start of
movement. Useful for heavy
leaves.
Y = Enable
No = Disabled
L
AST STROKE AT CLOSING:
The motors are activated at full
speed for 1s to facilitate lock-
ing of the electric lock.
Y = Enable
No = Disabled
R
EVERSING STROKE:
Before opening, while the gate
is closed, the motors thrust to
close for 2 s thus facilitating
release of the electric lock.
Y = Enable
No = Disabled
L
EAF 2 OPENING DELAY (2S):
Enables delayed start (at open-
ing) of leaf 2, avoiding interfer-
ence between leaves.
Y = Enable
No = Disabled
F
+