ENGLISH
14
Logic "EP" PULSES
GATE STATUS OPEN-A OPEN-B STOP OPENING SAFETY DEVICES
CLOSING SAFETY DEVICES
OP/CL SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf
Opens leaf for the partial
opening time
No effect
(OPEN disabled)
No effect
No effect
(OPEN disabled)
OPEN
Re-closes the leaf immediately (3)
Stops
operation
No effect
(if on part.opng. OPEN A disabled)
No effect
(OPEN disabled) (3)
No effect
(OPEN disabled)
CLOSING
Stops operation
No effect
(saves OPEN)
See paragraph 5.2
Locks and, on release,
reverses to open
Reverses to open for 2" (2)
OPENING
Stops operation (3) See paragraph 5.2 No effect
Locks and, on release,
continues opening
Reverses to close for 2" (2)
LOCKED
Restarts movement in reverse direction
(always closes after a Stop) (3)
No effect
(OPEN disabled)
No effect
(if it must open, it disables OPEN)
No effect
(if it must close, it disables OPEN)
No effect
(OPEN disabled)
Tab. 3/e
Logic "C" CONTROLS ALWAYS HELD DOWN PULSES
GATE STATUS OPEN-A (opening) OPEN-B (closing) STOP OPENING SAFETY DEVICES
CLOSING SAFETY DEVICES
OP/CL SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
No effect
Stops operation
(OPEN-A disabled)
OPEN
No effect
(OPEN-B disabled)
Closes the leaf
No effect
(OPEN-A/B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
CLOSING
Stops operation /
Stops
operation
No effect
Stops operation
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
Reverses to open for 2" (2)
LOCKED
/ Stops operation
Stops operation
(OPEN-A disabled)
No effect
Stops operation
(OPEN-A/B disabled)
Reverses to close for 2" (2)
Tab. 3/f
Logic "B" PULSES
GATE STATUS OPEN-A (opening) OPEN-B (closing) STOP OPENING SAFETY DEVICES
CLOSING SAFETY DEVICES
OP/CL SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf No effect
No effect
(OPEN-A disabled)
No effect
No effect
(OPEN-A disabled)
OPEN
No effect Closes the leaf
No effect
(OPEN-B disabled)
No effect
No effect
(OPEN-B disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A/B disabled)
CLOSING
Reverses to open No effect
Stops
operation
No effect
(saves OPEN-A)
Stops operation
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
Reverses to open for 2" (2)
OPENING
No effect No effect
Stops operation
(OPEN-A disabled)
No effect
Stops operation
(OPEN-A/B disabled)
Reverses to close for 2" (2)
LOCKED
Opens the leaf Closes the leaf
No effect
(OPEN-A/B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A/B disabled)
Tab. 3/g
Logic "B/C"
OPENING PULSE/CLOSING HOLD TO RUN CONTROLS
PULSES
GATE STATUS OPEN-A (opening) OPEN-B (closing) STOP OPENING SAFETY DEVICES
CLOSING SAFETY DEVICES
OP/CL SAFETY DEVICE EDGE SAFETY DEVICE
CLOSED
Opens the leaf No effect
No effect
(OPEN A disabled)
No effect
No effect
(OPEN A disabled)
OPEN
No effect Closes the leaf
No effect
(OPEN B disabled)
No effect
No effect
(OPEN B disabled)
No effect
(OPEN B disabled)
No effect
(OPEN-A/B disabled)
CLOSING
Reverses to open No effect
Stops
operation
No effect
(saves OPEN A)
Stops operation
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
Reverses to open for 2" (2)
OPENING
No effect No effect
Stops operation
(OPEN-A disabled)
No effect
Stops operation
(OPEN-A/B disabled)
Reverses to close for 2" (2)
LOCKED
Opens the leaf Closes the leaf
No effect
(OPEN A/B disabled)
No effect
(OPEN A disabled)
No effect
(OPEN B disabled)
No effect
(OPEN A/B disabled)
Tab. 3/h
(1) If maintained, it prolongs the pause until disabled by the command (timer function) (3) During the partial opening cycle, an OPEN A pulse causes total opening.
(2) If a new pulse occurs within 2 seconds after reversing, it immediately stops operation. NB.: Effects on other active pulse inputs in brackets.