844T
844T
Question and Answer IconNeed help?

Do you have a question about the FAAC 844T and is the answer not in the manual?

FAAC 844T Specifications

General IconGeneral
Model844T
ManufacturerFAAC
TypeControl Unit
Operating Voltage24 Vdc
Output TypeRelay
Maximum Current Consumption100mA
Operating Temperature-20°C to +60°C

Summary

EC Declaration of Conformity

Manufacturer and Product Declaration

FAAC S.p.A. declares the 844T control board conforms to essential safety requirements.

Installer Safety Guidelines

General Safety Obligations

Comprehensive safety instructions for installers concerning product installation, use, and maintenance.

Control Board Specifications and Connections

Technical Specifications

Details electrical and operational specifications for the 844 T control unit, including power, load, and temperature.

Electrical Connections (400V 3ph)

Diagram and instructions for 400V 3-phase electrical connections to the 844 T control board.

Control Board Component Description

J1 Plug for Accessories

Connects MINIDEC, DECODER, and RP RECEIVERS accessory cards to the 844 T electronic appliance.

J2 Low Voltage Terminal Board

Handles inputs (Open, Stop, Safety), outputs (Warning light), and low voltage power supply for accessories.

J3, J4, J5 High Voltage Terminals

Terminals for connecting flashlight (J3), motor (J4), and power supply (J5) for high voltage.

Programming and Operation Modes

Signalling LEDs

Describes the function of the 6 LEDs indicating terminal board input status.

Programming Automation Operation

Details how to program automation operation using microswitches SW1 to SW7.

Function Logics Explained

Explains available operating logics (Automatic, Semi-automatic, Safety, Dead Man) for the system.

Pause Time Settings

Defines the waiting time in the open position before re-closing for automatic logics.

Warning Light Operation

Configuration of the warning light's appearance during closing, including flashing.

Pre-flashing Setup

Setting the flashlight pre-flashing time (5 sec) before movement for warning.

Fault Conditions and Resolution

Describes fault conditions, their effects on operation, and how to restore normal function.

Limit Sensors and Motor Direction

Limit Sensors Connection Check

Procedure to verify correct connection and operation of FCC and FCA limit sensors.

Rotation Direction Check

Steps to check and correct the motor rotation direction for proper gate movement.

230V 3-Phase Electrical Connections

Diagram for connecting the 844 T appliance to a 3-phase 230V mains supply.

Operational Logic Tables

Logic A1 (Automatic)

Details gate status, pulses, stop, and safety device actions for Logic A1.

Logic A2 (Automatic Plus)

Details gate status, pulses, stop, and safety device actions for Logic A2.

Logic S1 (Safety)

Details gate status, pulses, stop, and safety device actions for Logic S1.

Logic S2 (Safety Plus)

Details gate status, pulses, stop, and safety device actions for Logic S2.

Logic E1 (Semi-Automatic)

Details gate status, pulses, stop, and safety device actions for Logic E1.

Logic E2 (Semi-Automatic Plus)

Details gate status, pulses, stop, and safety device actions for Logic E2.

Logic B (Semi-Automatic)

Details gate status, pulses, stop, and safety device actions for Logic B.

Logic C (Dead Man)

Details gate status, controls held down, pulses, stop, and safety device actions for Logic C.