1
L
N
230 V ~
*
230 V ~
L
N
L
1 ELECTRICAL CONNECTIONS
1) Before carrying out any work on the system, cut off the electrical power.
2) Provide the automated system’s power supply with an omnipolar switch featuring a contact
opening distance equal to or greater than 3mm.
3) Connect the wires as shown in the diagram. Should the motor turn in the opposite direction, do
not reverse the black and brown wires, as when setup is completed, the system will automatically
make correspond the up or down key with the correct sense of rotation of the motor.
* ATTENTION: IF A PUSH-BUTTON
CONTROL IS NOT USED, DO NOT
CO NNECT TH E BL AC K (OR RED)
WIRE.
ATTENTION: the push-button features step-by-step logic with dead-man control. Each time the key is pressed, a pulse
is sent to the motor (EXAMPLE: FIRST TIME IT IS PRESSED AND HELD DOWN: UP ; KEY IS RELEASED : STOP ; SECOND TIME IT IS
PRESSED AND HELD DOWN; DOWN etc.)
1.1 MOTOR CONTROLLED ONLY BY REMOTE CONTROL
1.2 MOTOR CONTROLLED BY REMOTE CONTROL AND PUSH-BUTTON
BROWN
BROWN
BLUE
BLACK
or
RED
BROWN
BLUE
YELLOW-GREEN
YELLOW-GREEN
BLACK
or
RED
BLACK
or
RED