page 21
FOR SWINGING GATE SYSTEMS Dip-B N°1=OFF
27
meccanica
FADINI
GB
27
UNIVERSAL ELECTRONIC CONTROL BOX
SINGLE-PHASE 230V 50/60Hz
Accessory
Electrical connections
Dip - Switch setting and LED indication of functions
Board power
supply 230V:
NEUTRAL
LIVE
24 25
Electronic control board power supply
230V - 50/60Hz ±10%
230Vac OUTPUT for
flashing lamp
max 25W
Electric latch and
flashing lamp 230V:
2322
l'apricancello
DIP-SWITCH-A N°4 and N°10:
ON: Pre-flashing before movement
OFF: No pre-flashing
4
ON: Out of service in Dwell phase
Automatic mode (by Dip 3= ON)
OFF: Powered, ie. in service in Dwell phase
Automatic mode (by Dip 3= ON)
10
230Vac OUTPUT for
electric latch. Important:
power supply must be off
during Dwell time by
Dip-A n°10=ON
Power connections
to Pulin 3 LEDs:
28 2627
3
OUTPUT
24Vdc - 5W max
24Vdc-5W Output:
Terminals for
the connections
of the LEDs of the
push buttons
Pulin 3
29 30
+ -
ELECTRICAL CONNECTIONS ON SWINGING GATE MODE - Dip Switch B n°1=OFF
Output for single-
phase motors
230V 350W max:
In case of
one motor only:
1) Connect power supply to the terminals Motor M1
2) No gate delay in opening by Dip-A N°8=ON
3) Set the trimmer Gate Delay in Closing to zero
motor
delayed
in closing
DWELL TIME
1s - 220s
MOTOR RUN TIME
OPEN-CLOSE
0s - 60s
motor
delayed
in opening
M1
COMMON
16 17 18 19 20 21
M2
COMMON
GATE DELAY
IN CLOSING
0s - 10s
In case of
2
motors:
Gate delay in Opening, with a fixed time of 2s: if required, it
must be enabled by Dip-A N°8=OFF
DIP-SWITCH-A N°8:
ON: No gate delay in opening
OFF: 2s gate delay in opening enabled
8
-
+
-
+
-
+
Gate electric lock:
14 15
Power supply output 12Vac/dc or 24Vac/dc for an electric lock,
15VA max. The electric lock is to be fitted onto the gate operated
by the M1 motor, delayed in closing cycle.
STRIP
JUMPER
Power supply for a
mechanical release lock
3 2 1
LOCK
SETUP
3 2 1
LOCK
SETUP
3 2 1
12V
12V electric lock
power supply
3 2 1
24V
24V electric lock
power supply
Power supply for a magnetic
lock to hold the gate/s
on gate stop/s
AC
= alternated current
output
DC
= direct current
output
ELECTRIC LOCK
TIME
0,5s - 20s
-
+
24V Output:
FADINI
Astro 43
FADINI
12 13
24V ac OUTPUT - max load:
No. 3 pairs of photocells
No. 1 radio receiver
No. 1 LED Chis 37 / Chis-E 37 key-switch
Instructions are attached to the related control
accessories

Related product manuals