Conversational mode
118
Semi-automatic calibration (with a probe).
This option is only available when using a tabletop probe
installed on the machine.
On a milling model, it may be used to calibrate the length
or radius of the milling tools.
On a lathe model, it may be used to calibrate the offsets
of any tool.
A. Machine data. Position of the axes, tool and active
tool offset, real spindle speed and real feedrate of the
axes.
B. Area to define the calibration data.
The tool must be in the spindle. After the calibration, the
wear is reset to zero.
When changing the tool data, the tool table data is
updated after calibration.