ERROR 010
DESCRIPTION
If the VHM outlet is
activated and TV does not
rise 3 or more degrees in 2
minutes, if TV<=75.
CONSEQUENCE
It is only possible to operate
in Convection mode
ERROR 023
DESCRIPTION
Fluepipe motor faulty
CONSEQUENCE
The oven is completely
disabled
ERROR 011
DESCRIPTION
The CC output operates for
12 minutes and TC does
not rise 3 or more degrees.
CONSEQUENCE
The oven is completely
disabled.
ERROR 024
DESCRIPTION
Communication error. The
chamber card does not
respond.
CONSEQUENCE
The oven is completely
disabled
ERROR 012
DESCRIPTION
The controller NTC reaches
60ºC, but does not exceed
70ºC.
CONSEQUENCE
The oven operates normally
and the bell is not heard.
This message should be
displayed every 3 minutes
for 30 seconds.
ERROR 025
DESCRIPTION
Communication error. The
control holder card does
not respond.
CONSEQUENCE
The oven is completely
disabled
ERROR 022
DESCRIPTION
The controller NTC exceeds
70ºC.
CONSEQUENCE
The oven is completely
disabled.