Thank you for choosing Fairland Inverter-Plus heat pump.
This manual provides you necessary information for optimal
use and maintenance, please read it carefully and keep it for
subsequent use.
INSTALLATION AND
USER MANUAL
EN-DE
vivapool.pl
vivapool.pl
vivapool.pl

Questions and Answers

  • R
    rwolfeJul 27, 2025
    What to do if my Fairland Heat Pump display is normal but there is no heating?
    • B
      Becky JacksonJul 28, 2025
      If your Fairland Heat Pump's display is normal, but it's not heating, it might be due to the set temperature being too low. Ensure you set the temperature to a proper heating level. Also, consider that there might be a 3-minute start delay; wait patiently to see if the heating starts.
  • C
    Caroline FrazierAug 7, 2025
    Why is my Fairland Heat Pump not running?
    • M
      Mary ScottAug 7, 2025
      If your Fairland Heat Pump isn’t running, it could be due to several reasons: * There might be no power. In this case, wait until the power recovers. * The power switch might be off. Ensure the power switch is turned on. * A fuse might have burned out. Check the fuse and replace it if necessary. * The breaker might be off. Check the breaker and turn it on.
  • J
    julieburtonAug 17, 2025
    What to do if Fairland Inverter-Plus fan is running but with insufficient heating?
    • T
      Trevor BallardAug 17, 2025
      If your Fairland Heat Pump's fan is running but there is insufficient heating, check for the following: * The evaporator could be blocked. Remove any obstacles. * The air outlet might be blocked. Clear any obstructions. * There may be a 3 minutes start delay. Wait patiently.

Summary

General Information

Kind Reminders and Warnings

Important notes on power-off memory, usage limitations, handling, and fire prevention.

Operations

Installation and Maintenance

Professional Installation Requirement

Emphasizes that installation must be performed by a professional team for safety and to prevent damage.

Wiring and Protection Devices

Specifies breaker, fuse, and cable types for safe and compliant electrical connections.

Wiring Diagrams

Illustrates electrical connections for 230V and 400V power supplies for proper setup.

Trial Operation

Inspection Before Use

Checklist for verifying all wirings, connections, and physical obstacles before initial power-on.

Initial Startup and Testing

Steps for performing the initial startup and testing of the heat pump after installation.

Maintenance and Winterizing Procedures

Troubleshooting Common Faults

Failure Codes

Wiring Diagrams for Heating Priority

Fairland Inverter-Plus Series Specifications

General IconGeneral
ModelInverter-Plus Series
Noise Level50 dB(A)
ControlInverter
Heating Capacity12 kW
Power Supply220-240V, 50Hz
Operating Temperature Range (Heating)-15°C to 43°C