*941367-00*
941367-00
Motorized Electric Latch Retraction
MEL 24/25 Series
Installation Instructions
1 Remove end cap
These instructions are for MEL conversion kits or MEL
devices with preinstalled motors.
Parts
Do not discard
MEL 6' cable with motor cable
(47269206)
MEL motor mounting
4-20 x ¹⁄₄" FHP screws (qty 2)
Motor cable
only
(114320)
MEL motor
assembly
MEL
cover plate
Allegion Connect accessories available to order
106198 MEL-CON adapter cable with 8-pin connector
040069 MEL motor cable + MEL-CON adapter cable with 8-pin
connector
If MEL is preinstalled in the device:
If installing the MEL conversion kit, follow
the instruction steps as written.
Mark and Prepare 2 Holes
a
b
c
#25
#10-24
Wood/Madera/Bois
Metal/Metal/Métal
¹⁄₈" (3 mm) x 1" (25 mm)
Follow original device instruction up to the point
where this end mounting bracket step has been
completed.
A.
Complete MEL wiring per steps 15-21 of this
instruction.
B.
Return to original device instruction at point you left
off, and complete installation.
C.

Other manuals for Falcon 25 Series

Question and Answer IconNeed help?

Do you have a question about the Falcon 25 Series and is the answer not in the manual?

Falcon 25 Series Specifications

General IconGeneral
Microwave Frequency10.525 GHz
Detection MethodMicrowave + PIR
Coverage Angle90 degrees
Current Consumption25 mA
Tamper OutputNC, 28VDC, 0.15A
Power Input12V DC
Input Voltage12V DC