021519
MCS30 Rev B
13
5.0 Maintenance, Service, and Storage
Maintenance: No scheduled maintenance is required, other than the replacement of items that failed inspecon.
Service: There are no specic service requirements for this system component.
Storage: If the unit is removed from its installaon locaon, it should be stored in a dry area free of corrosive elements that may harm
or cause the product not to funcon.
6.0 Inspecon
6.1 Pre-Use Inspecon:
6.1.1 Inspect the addional equipment used on the davit arm per the user instrucon manual for the specic equipment. Do not use
if the equipment fails inspecon.
6.1.2 Inspect the Conned Space Davit System thoroughly for damage. Inspecon should include checking the structure for dents,
cracks, deformed, or bent tubing.
6.1.3 Inspect all hardware for damage, wear, or missing parts.
6.1.4 Check all rollers and pulleys for to ensure proper movement. Check for damage such as cracks, chips, and excessive wear.
6.1.5 Ensure all detent pins are properly secured before every use.
Do not use the FallTech Conned Space Davit or addional equipment if it fails any part of this inspecon.
6.2 Inspecon Frequency:
Pre-Use: Inspect the Conned Space Davit System and addional equipment weekly as outlined in secon 6.1. All installaons must be
approved to local standards by a Qualied Person.
Annually: The Conned Space Davit System and addional equipment must be inspected by a Qualied Person annually and recorded on
the Inspecon Record provided or equivalent document.