COOKERS ERROR CODES
In case of error, the device displays error codes for support purposes.
The display of the cooking area shows the error code alternating 'E' with
other symbols and numbers.
Error
code
Description Possible
causes
Solution
+
+ 0 + 3
Continuous acti-
vation of a key
- Metal objects
above the
keyboard
- water over the
keyboard
- Move the metal
objects
- Dry the water
+
+ 2 + 1
Internal tempera-
ture above 85°C
- covered or
insucient ven-
tilation areas
- Allow internal heat
dissipation
+
+ 3 + 1
Incorrect congu-
ration
- conguration
error
- Contact Technical
Supportstenza
tecnica
+
+ 4 + 2
Internal supply
voltages too high
or low
Overcharging
due to atmo-
spheric dischar-
ge, electrical
system failure or
incorrect power
connection
- Contact Technical
Support
+
+ 4 + 7
No communi-
cation between
keyboard and
inductor modules
- Communi-
cation cable
damaged or
disconnected
- Damaged in-
ductor module
- Contact Technical
Support
+
+ 2 + 0
+
+ 2 + 2
+
+ 3 + 5
+
+ 3 + 6
Control keyboard
internal error
- Contact Technical
Support
+ 2
Temperature limi-
ts were exceeded
in the cooking
area
- Empty sauce-
pan
- unsuitable
saucepan type
- saucepan or
glass too hot
- ll the saucepan
- use a suitable
saucepan
- remove the sauce-
pan and allow the
area to cool down
+ 3
Unsuitable sau-
cepan
- The saucepan
has little ferritic
material
- The saucepan
caused an error
in the inductor
module
- Inductor
failure
- Use a suitable
saucepan
- Remove the sauce-
pan, wait 8 seconds
and try again
- Contact Technical
Support
+ 4
Incorrect congu-
ration
- inductor con-
guration error
- Contact Technical
Support
+ 5
No communi-
cation between
keyboard and
generator
- Faulty or
disconnected
LIN cable
- Incorrect
electrical con-
nection
- Internal fault
- Conguration
error
- Contact Technical
Support
- Check terminal
board electrical
connection
- Contact Technical
Support
- Contact Technical
Support
+ 6
Incorrect power
supply
- Out-of-range
supply voltage
- Incorrect
supply voltage
frequency
- Inductor
failure
- Check that the
supply voltage is
correct: voltage and
frequency.
- Contact Technical
Support
+ 7
Internal inductor
failure
- Contact Technical
Support
+ 8
Cooling fan not
working
- Dirty fan
- Fan Failure
- Clean the air vents
- Contact Technical
Support
+ 9
Faulty inductor
temperature
probe
- Faulty inductor
temperature
probe
- Contact Technical
Support
+
Internal inductor
failure
- Contact Technical
Support
+
Inductor tempe-
rature probe has
a xed value
- glass too hot
- faulty probe
- Cool the glass
- Contact Technical
Support
Note:
Not each failure can be delected automatically by the system, e.g. in case of
defect of the User interface power supply.
Note:
Not each failure can be delected automatically by the system, e.g. in case of
defect of the User interface power supply.
COOKER HOOD
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged outside
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a
pipe, to an external output.
The outlet pipe must have:
a diameter not less than that of the hood fitting.
a slight slope downwards (drop) in the horizontal sections to prevent con-
densation from flowing back into the motor.
the minimum required number of bends.
the minimum required length to avoid vibrations and reduce the suction
performance of the hood.
You are required to insulate the pipes if it passes through cold environ-
ments.
In the presence of motors with 800m
3
/h or higher, a check valve is present
to prevent external air flowing back.
Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by
energy other than electricity, the negative pressure in the room must not exceed 4 Pa
(4 x 10-5 bar).
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the Carbon-Zeo (option-
al) filters to be purified and recycled in the environment.
Ensure that the Carbon-Zeo filters are assembled into the
hood, if not, install them as indicated in the assembly instruc-
tions.
ASSEMBLY INSTRUCTIONS
only intended for qualied personnel
The hood can be installed in various congurations.
The generic assembly steps apply to all installations; for each case,
follow the specic steps provided for the required installation.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FALMEC Zero and is the answer not in the manual?

FALMEC Zero Specifications

General IconGeneral
BrandFALMEC
ModelZero
CategoryCooktop
LanguageEnglish