Installer
38
Modulating: FIXED TIME
*
Modulate under %
*
Setting of the ventilation percentage, below which the control computer will apply
modulating control to the linearly controlled part.
This applies to fans that cannot be controlled below this percentage. Linearly
controllable fans usually have a minimum ventilation level. The control computer cannot
ensure reliable fan control below this level. Modulating control can be used below this
level.
Cycle time
*
Setting of the duration of a cycle (ON plus OFF period).
Calc.ON/OFF-Time
*
Readout of the actual ON/OFF time.
INSTALLER VENTILATION SETTINGS tab page Vortex
Description
Readout of the name of the function.
Output address
Setting of the analog output address.
Analog type
Setting indicating the analog control type
Extra analog
Setting of the analog output address.
INSTALLER VENTILATION SETTINGS tab page Relay
Rotation time
Setting of the period after which the relays rotate.