Farnell TSV 70 - Setting Up Procedure; Accessing Internal Components; Voltage Range and Current Limit Setup; Meter Calibration

Default Icon
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACCESS.
Access
to
the
circuitry
may
be
gained
by
first
removing
the
rear
panel,
and
then
withdrawing
all
the
covers,
bottom
two
sides
and
top,
which
are
located
in
slots
in
the
four
extruded
bar
chassis
members.
1)
Setting
the
Voltage
Ranges,
and
Current
Limit.
2)
3)
4)
5)
6)
SECTION_V
SETTING
UP
PROCEDURE.
1)
2)
3)
Set
the
"RANGE"
Switch
to
35V,
10A.
Set
the
COARSE
and
FINE
front
panel
controls
to
fully
clockwise.
Apply
mains
input
to
the
unit
and
adjust
T2
on
circuit
board
No. 1
to
give
35.5
volts
output.
With
the
CURRENT
LIMIT
control
set
fully
anti
clockwise,
and
a
short
circuit
applied
to
the output
terminals,
adjust
T3
circuit
board
No.
1
to
give
zero
output
current.
Remove
the
short
circuit.
Connect
a
load
to
the
output
terminals
and
adjust
it
to
give
11
Amps
output
current,
with
the
"CURRENT
LIMIT"
control
fully
clockwise.
Adjust
T4
circuit
board
NO.
1
until
the output voltage of the
unit
just
begins
to
fall
at
11
Amps.
Disconnect
the
load.
Circuit
board
No.
1
is
located
on
the
right
hand
side
of
the
unit
viewed
from
the
front,
and
is
the
.circuit
board
nearest
to
the
front
panel.
Set
the
range
switch
to
70v,;
5A.
Set
the
COARSE
and
FINE
voltage
control
fully
clockwise.
Setting
the
meter
fu1l
scale
deflections.
Adjust
Tl
circuit
board
No.
1
to
give
71
volts
output.
With
the
RANGE
Switch
on
the
70V
5A
position
adjust
the
output
voltage
of
the
unit
by
means
of
the
COARSE
and
FINE
front
panel
controls
togive
70
volts
output,
as
indicated
on
an
accurate
external
meter.
Set
Tl01
until
the
front
panel
voltmeter
reads
70
volts
(full
scale)
With
the
RANGE
Switch
on
the
35V
lOA
position
adjust
the
output
voltage
of
the
unit
to
give
35
volts
as
indicated
on
an
accurate
external
meter.
Set
T102
until
the
front
panel
voltmeter
reads
35
volts.
(full
scale).
With
the
RANGE
Switch
on
the
35V
1OA
position
apply
an
accurate
external
ammeter
across
the
output
terminals.
Adjust
the
CURRENT
LIMIT
Control
to
give
a
reading
of
10
amps
on
this
external
meter.
Set
Tl04
until
the
- 8
front
panel amneter reads
10
amps
(full
scale).