EasyManua.ls Logo

Farnell TSV 70 - User Manual

Default Icon
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
A
high
performance
power
supply
with
an
output
of
either
0-70V,
5A
or
0-35V,
10A
Farmel
TSV
70
power
supply
uENT
Publication
PS
3
The
TSV
70
laboratory
bench
power
supply
is
a
source
of
stabilised
d.c.
voltage
continuously
variable
over
two
ranges,
0
to
70
volts
at
0
to
5
Amps
or
0
to
35
volts
at
0
to
10
Amps,
selected
by
a
switch.
A
switch
isolates
the
output
voltage
which
may
be
selected
by
coarse
and
fine
controls
prior
to
connection
to
the
load.
Conversely
the
load
may
be
disconnected
by
the
same
switch
without
switching
off
the
mains
supply.
Output
voltage
and
current
are
monitored
independently
by
dual
scale
meters.
Remote
sensing
facilities
are
provided
to
ensure
optimum
performance
when
sup
plying
distant
loads.
Overload
protection
is
by
adjustable
constant
current
limiting.
The
use
of
forced
air
cooling
and
the
latest
components
and
production
techniques
has
helped
to
reduce
size
and
weight
without
resorting
to
switching
techniques.
The
specification
is
consequently
very
good
and
the
unit
does
not
generate
radio
frequency
interference.A
rack
mounting
version,
the
TSV
70R,
is
available
to
special
order.
Question and Answer IconNeed help?

Do you have a question about the Farnell TSV 70 and is the answer not in the manual?

Summary

Farnell TSV 70 Power Supply

Product Overview

Introduces the Farnell TSV 70 as a high-performance, stabilised DC voltage power supply.

Instruction Manual

Product Identification

Identifies the manual for the Stabilised Voltage Supply Type TSV.70 MK. II.

Introduction

Supply Description

Details the TSV.70 Mk. II as a stabilised DC voltage supply with variable ranges and overload protection.

Operating Instructions

Mains Input Configuration

Instructions for setting the transformer tapping to match the mains input voltage.

Front Panel Controls

Explanation of the Input On/Off, Voltage Adjust, and Range controls on the front panel.

Meters and Indicators

Describes the output voltage and current meters and their automatic range selection.

Current Limit Adjustment

Guidance on setting the adjustable constant current limit for overload protection.

Circuit Description

Overall Supply Architecture

Describes the supply's mains transformer, rectifiers, capacitors, and series regulators.

35 V 10 A Range Circuitry

Details the circuit configuration for the 35V, 10A output range, including parallel systems.

Control Circuitry Function

Explains the role of the main control circuit board and its reference voltage generation.

Specification Summary

Mains Input and Variation

Specifies mains input voltages (210-240V, 105-120V) and tolerated variation (±10%).

Output Capability Range

Defines output as 0-70V at 0-5A or 0-35V at 0-10A, continuously variable.

Metering and Regulation

Covers voltmeter/ammeter ranges, line, and load regulation figures.

Ripple, Noise, and Temperature

Specifies ripple/noise limits, operating temperature range, and overload protection.

Physical Dimensions and Weight

Provides the unit's dimensions (width, depth, height) and weight.

Setting Up Procedure

Accessing Internal Components

Instructions for gaining access to circuitry by removing the rear panel and covers.

Voltage Range and Current Limit Setup

Step-by-step procedure to set voltage ranges and current limits using internal controls.

Meter Calibration

Procedure for calibrating the front panel voltmeter and ammeter to external references.

Performance and Applications

Series Operation

Guidelines for connecting units in series to achieve higher output voltages.

Parallel Operation

Instructions for connecting units in parallel to increase current capability.

External Sensing Operation

Details using sense terminals to correct for voltage drop in leads, with stability considerations.

Stability Factors

Load Change Effects

Details steady load change response and transient response to pulsed loads.

Mains Supply Influence

Explains how mains surges can affect output and suggests input filtering.

Temperature Variation Impact

Describes output variation caused by component value changes due to temperature.

Farnell TSV 70 Specifications

General IconGeneral
BrandFarnell
ModelTSV 70
CategoryPower Supply
LanguageEnglish