FAURE-HERMAN
COMPONENT MAINTENANCE MANUAL
744-082 / 744-082-3
28-49-91
PAGE 110
MAR 31/07
- Wait at least 5 min.
- Close switch I
1
.
- Check that the quantity of fuel remaining indicated on the RH display is the same
as that noted above.
- On model 744-082, open switch I
4
.
(9) Checking the spare indicator light function
This indicator light should come on when the calculated flight time drops below 40 min.
- Select the AS332 helicopter using the rear RH selector.
- Select the "kg" mode using the rear LH selector.
- Set LF generator G1 to a frequency of 70 Hz and an amplitude of 100 mV rms, then
switch off.
- Close switch I
5
.
- Close switch I
1
.
- Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "PRESET" and select a quantity
of remaining full of 060 on the RH display using the "-/+" switch.
- Set the "DEBIT-FLOW/T-Q.REST/PRESET" switch to "T-Q.REST".
- Switch on LF generator G1.
- Increase the LF generator frequency so as to reduce the remaining flight time.
- Check that the spare indicator light comes on when the LH display (remaining flight
time) reads 40 min.
- Decrease the LF generator frequency so as to increase the remaining flight time.
- Check that the spare indicator light goes out when the LH display (remaining flight time)
reads 46 min.
The document reference is online, please check the correspondence between the online documentation and the printed version.