FAURE-HERMAN
COMPONENT MAINTENANCE MANUAL
744-082 / 744-082-3
28-49-91
PAGE 303/304
JULY 17/13
- To remove an edge-lighting lamp (540), remove filter (530) and the lamp and retain sleeve
(550).
G. Removing receptacle connector
(1) Flowmeter 744-082
- Mark and unsolder the connecting wires.
- Remove four attaching screws (310) and retain washers (320), nuts (330) and terminal lug
(340).
- Remove the connector (300).
(2) Flowmeter 744-082-3 (See IPL, figure 7)
- Mark and unsolder the connecting wires and components
- Remove four attaching screws (70) (80), retain washers (90), terminals (110), nuts (100),
lug (120), bar (130) and square (140).
- Remove the connector (60).