9
Approximate STP / IST Specications
Operating
Pressure (PSI)
PMA
Length (in)
S.F.
Amps
Locked
Rotor Amps
Winding Resistance
Model Description R-B R-O B-O
STP33* 208 / 230 V, 60 Hz, 1 ph 27 16 3.1 11 27 19 8
STP75* 208 / 230 V, 60 Hz, 1 ph 30 18.25 6.1 27 20 17 3
STP150* 208 / 230 V, 60 Hz, 1 ph 32 21 10.5 39 15 13 2
STPH150* 208 / 230 V, 60 Hz, 1 ph 45 21.75 10.5 39 15 13 2
STP200+ 208 / 230 V, 60 Hz, 1 ph 36 23.75 11.4 41 4.6 3 1.8
STPH200+ 208 / 230 V, 60 Hz, 1 ph 46 24.5 11.4 41 4.6 3 1.8
STP75B++ 200 / 250 V, 50 Hz, 1 ph 37 20.5 5.6 23 27 23 4
STP150B++ 200 / 250 V, 50 Hz, 1 ph 38 22.75 10.2 28 16 13 3
STPH150B++ 200 / 250 V, 50 Hz, 1 ph 48 23.25 10.2 28 16 13 3
STP200B‡ 200 / 250 V, 50 Hz, 1 ph 37 25.75 10.9 36.5 5.5 3.5 2
STPH200B‡ 200 / 250 V, 50 Hz, 1 ph 44 26.25 10.9 36.5 5.5 3.5 2
STP75C 380-415 V, 50 Hz, 3 ph** 37 19.75 2.1 10 29 29 29
STP150C 380-415 V, 50 Hz, 3 ph** 38 21.75 3.4 14 14 14 14
STPH150C 380-415 V, 50 Hz, 3 ph** 48 22 3.4 14 14 14 14
STP200C 380-415 V, 50 Hz, 3 ph** 37 23.5 4.1 22.5 11.6 11.6 11.6
STPH200C 380-415 V, 50 Hz, 3 ph** 44 24 4.1 22.5 11.6 11.6 11.6
IST / STPVS2^ 190 V, 70 Hz, 3 ph† 24-42 20 6.7 N / A 2.5 2.5 2.5
ISTVS4 / STPVS4^^ 190 V, 70 Hz, 3 ph† 24-42 25 14.4 N / A 1.2 1.2 1.2
Symbol Key
* Use a 15 µF, 370 V, single phase, 60 Hz capacitor
+ Use a 40 µF, 370 V, single phase, 60 Hz capacitor
++ Use a 15 µF, 440 V, single phase, 50 Hz capacitor
‡ Use a 40 µF, 440 V, single phase, 50 Hz capacitor
† 190 V, 70 Hz, 3 ph power to variable speed units is output from IST-VFC or MagVFC only (VFC’s are powered
by 200-250 V, 50 or 60 Hz, single or 3 phase input)
^ Use with IST-VFC or MagVFC controller only, No Capacitor
^^ Use with MagVFC controller only, No Capacitor (3 phase input is required for full VS4 output))
** No capacitor is used with 3 phase pump motor assemblies
Note: The models listed in the table above may contain (ANZ) for ANZEX certied pumps, or (ATX) for ATEX certied
pumps.
Warning
FE Petro’s STPs are designed for use with motor fuels, and they are UL listed for blend
concentrations of:
Standard Models AG (Alcohol / Gasoline) Models
0% - 15% ethanol or methanol and gasoline 0% - 85% ethanol or methanol and gasoline
20% MTBE with 80% gasoline 20% MTBE with 80% gasoline
20% ETBE with 80% gasoline 20% ETBE with 80% gasoline
17% TAME with 83% gasoline 17% TAME with 83% gasoline
Diesel, fuel oil, avgas, jet fuel, or kerosene may also be used with our PMAs. The maximum liquid
viscosity for a product is 70 S.S.U. at 60° F.
Using our PMA in liquids other than those mentioned above has not been tested. The reaction of
other liquids with seals and wetted surfaces of the pump is unknown. A hazardous situation may
result from using other liquids with our pump.