Arsenic, chromium and other wood pre-
servatives;
Materials for pesticide treatment on boot
and ship hulls.
To minimise the unwanted intake of these
materials:
Use dust extraction matched appropriately
for the developing dust.
Use personal protective equipment, such as
a P2 filter-class dust protection mask.
Provide for good ventilation of the work-
place.
The risk from inhaling dusts depends on the
frequency how often these materials are
worked. Materials containing asbestos may
only be worked by specialists.
Wood and light-metal dust can
cause spontaneous combustion
or explosions.
Hot mixtures of sanding dust and paint/var-
nish remainders or other chemical materials
in the filter bag or the vac filter can self-ignite
under unfavourable conditions, such as spark-
ing from sanding metal, continuous sunlight
or high ambient temperatures. To prevent
this:
Avoid overheating the material being
sanded and the power tool.
Empty the dust collector/container in time.
Observe the material manufacturer’s work-
ing instructions.
Observe the relevant regulations in your
country for the materials being worked.
Emission values for sound and vibration
(Two-figure – specifications as per ISO 4871)
CAUTION
Sound emission KBM80U KBM80auto
Measured A-weighted sound power level L
wA
(re 1 pW), in decibels 95 95
Measuring uncertainty K
wA
, in decibels 3 3
A-weighted emission pressure power level
measured at the workplace L
pA
(re 20 µPa), in
decibels 84 84
Measuring uncertainty K
pA
, in decibels 3 3
Measured C-weighted peak sound pressure
level L
pCpeak
, in decibels 101 101
Measuring uncertainty K
pCpeak
, in decibels 3 3
Vibrations
Weighted acceleration, in
m/s
2
ft/s
2
1.2
3.9
1.2
3.9
Measuring uncertainty K, in
m/s
2
ft/s
2
1.5
4.9
1.5
4.9
REMARK: The sum of the measured emission value and respective measuring inaccuracy rep-
resents the upper limit of the values that can occur during measuring.
Wear ear protection!
Measured values determined in accordance with the corresponding product standard.