TECHNICAL SPECIFICATIONS
Power supply
12 Vdc
Consumption
300 mA
Audio output power
900 mW
Output impedance
8 ohms
Call signal
Electronic call tone
Wiring required
2 wires between central and secondary
Type of wire depending on effective distance
SAFETY INSTRUCTIONS
To prevent risk of electrical shock, do not open the equipment or expose it to
water or moisture.
The equipment must be installed in such a way that its ventilation is not obstructed.
For example, it must not be placed behind a sofa, cupboard or any other place where
the ventilation slots are blocked.
Metallic objects must not be inserted in the ventilation grids.
Do not install near heat sources (kitchen, radiators,etc.) or damp places
(bathroom, swimming pool, kitchen sink, etc.)
If the equipment is not going to be used for a long period, it should be unplugged.
Dimensions and weights
WEIGHT (gr)
CM-204 432.4 170 mm 155 mm 55 mm
CM-206 671.6 255 mm 155 mm 55 mm
WIDTH LENGTH HEIGHT
CM-211 690 255 mm 155 mm 55 mm
CM-200 308 170 mm 155 mm 55 mm
AWG 24 AWG 22 AWG 20 AWG 18 AWG
Diameter 0.5 mm 0.65 mm 0.8 mm 1.00 mm
Cross Section 0.21mm
2
0.33mm
2
0.52mm
2
0.83mm
2
Distance 120 m 200 m 300 m 480 m