No es necesario segregar la instalación según esta jerarquía ya que el sistema se
adapta a las necesidades de la instalación.
NOTA IMPORTANTE:
Programación de parámetros por el instalador.
Para programar - modificar dichos parámetros ver «Seccion II: Manual de Programa-
ción», (al final de este manual).
MASTER Panel:
· Apartment terminals programming are always done from the panel activated as MAS-
TER.
· Any installation can only have one MASTER panel at a time, whether a single or
multiple block installation, once configured as a sub-block, block or general entrance.
· A street panel is configured as a MASTER via the SW1 amplifier button. If the SW1
button is pressed 3 times quickly, it is activated as a MASTER panel and a confirmation
tone sounds (beep-beep), after 2 seconds. You can also configure it via a code on the
keypad, see Section II.
· When a panel is selected as MASTER, it notifies the rest of the situation and if another
was previously configured, it would automatically stop being so.
· If there are various blocks in an installation, we recommend using the general entrance
panel as MASTER since it allows you to program all of its telephones.
· Once having completed the terminal´s configuration, we recommend deactivating the
MASTER panel to avoid accidentally reprogramming terminals.
· The panel deactivates itself from master mode following the same activation
procedure: 3 quick presses of the SW1 button. A deactivation tone sounds (bop), after
2 seconds. You can also deactivate it via a code on the keypad, see Section II.
The DUOX amplifier can be configured to allow for the operation as a general
entrance, block entrance or sub-block entrance.
· The DUOX system uses 6 digit house terminal addresses.
· These call code digits are organised as follows: BBSSNN:
- BB: indicates the Block number, (from 00 to 99).
- SS: indicates the sub-Block number, (from 00 to 99).
- NN: indicates the sub-Block house number, (from 00 to 99).
You do not have to segregate the installation according to this hierarchy since the
system adapts to the installation´s needs.
IMPORTANT NOTE:
Programming the installer´s parameters.
To program or change these parameters see «Section II: Programming Manual», (at
the end of this manual).
Configuration - Programming the Amplifier