Installing the product
· Connect the pump to the pipe and this one to its
housing inside the fountain slide (1-2) and press it
well down.
· Insert the supply cable through the hole in the rear
part of the fountain slide (3).
· Put the 4 rubber feet in their housing on the bottom of
the bowl (4).
· Before inserting the active carbon filters in their
housing rinse them under tap water in order to remove
dust and excess carbon (5).
· Assemble the slide to the bowl (6).
· Insert the supply cable into its housing in the rear part
of the bowl (7).
· Fill the bowl with water.
· Connect the pump supply cable to the adapter and this
one to the socket.
IMPORTANT: never connect the pump to the
power supply before filling the bowl with
water.
How to adjust the pump flow rate
· Disconnect the pump power cable from the adapter.
· Take the slide away from the bowl by slightly pulling it
upwards (8).
· Adjust the flow rate by using the small lever (11).
· Reassemble the product following the steps in the
reverse way.
Product maintenance
· Regularly check that the water level is always over the
minimum water level shown on the product; if not,
immediately add water.
· Periodically clean the entrance water grids and check
that they are not obstructed.
· Check the filters weekly and if they are obstructed
rinse them under water.
· It is recommended to replace the filter every month
,
or when it is clearly obstructed.
· Check periodically the pump working condition and if
necessary clean it; it is recommended to clean it very 3
months.
Filter cleaning and replacing
· Disconnect the pump supply cable from the adapter
cable.
· Take the slide away from the bowl pulling it slightly
upwards (8).
· Remove the filter and rinse it or replace it with a new
one.
· Reassemble the product following the steps in the
reverse way.
Pump maintenance
· Disconnect the pump supply cable from the adapter
cable.
· Take the slide away from the bowl pulling it slightly
upwards (8).
· Take the pipe away from the pump (9).
· Remove the pump cover, remove the rotor and clean it
using a small soft brush under warm water (do not use
detergents or abrasives) (10).
· Reassemble the product following the steps in the
reverse way.
WARRANTY. Ferplast guarantees this product within
the limits of the present clause and of the current legal
regulation. The guarantee is valid only against
manufacturing faults and it includes free product
repair or replacement. The guarantee is not valid for
damage and/or faults caused by negligence, wear,
improper use, accidents, tempering, incorrect repairs,
purchase not confirmed by receipt. Filters are excluded
from product warranty. They are available as spare kit.
IMPORTANT - Within the European Union, a
crossed-out wheelie bin symbol on the product,
documentation or packaging indicates that the
product cannot be disposed of in the regular
household waste stream, in compliance with EU
Directive 2012/19/EC and with current local
regulations. The product must be disposed of at
recycling centres or authorised waste disposal
centres for electrical and electronic equipment, in
accordance with current legislation in the country
where the product is found. Incorrect disposal of
this type of waste can have a negative impact on
the environment and human health, caused by
the potentially hazardous substances produce by
electrical and electronic equipment. Correct
disposal of these products will also contribute to
the efficient use of natural resources. Further
information is available from the product retailer,
the competent local authorities and national
manufacturers organisations.
IT
Complimenti per aver scelto la fontanella per gatti e cani
di piccola taglia VEGA, progettata da Ferplast per
promuovere la salute del vostro animale, stimolando il
desiderio di bere e riducendo così i problemi urinari.
Utilizzarla sarà molto semplice. Bastano pochi minuti di
manutenzione ogni mese per avere acqua sempre pulita
e cristallina.
LEGGETE E SEGUITE ATTENTAMENTE LE
ISTRUZIONI INDICATE NEL PRESENTE
MANUALE PRIMA DI UTILIZZARE IL
PRODOTTO
· Assicuratevi che il voltaggio indicato sulletichetta del
trasformatore corrisponda a quello della rete di
alimentazione.
· Prima di operare qualsiasi attività di manutenzione,
assicuratevi di aver scollegato lapparecchio dalla rete
di alimentazione.
· Non collegate la pompa alla presa di corrente prima di
aver riempito la ciotola d’acqua.
IMPORTANTE: non lasciare mai la pompa
accesa a secco, senza la presenza dellacqua!
· Il liquido non deve superare la temperatura di 35°C.
· Mantenete sempre il livello dellacqua sopra la linea di
‘’minimun water level’’ indicata nel prodotto.
· I cavi di alimentazione della pompa e del trasformatore
non possono essere né sostituiti né riparati: se
danneggiati, sostituite l’intero componente (pompa
e/o trasformatore). Il cavo non va mai tagliato.
· Lapparecchio è destinato al solo uso interno.

Related product manuals