Removing the diverter valve motor head
A
Before carrying out the following instructions it is advisable to protect the area and the boiler’s PCB housing
against accidental water spillage.
fig. 47
Isolate the power supply and close the Gas isolation valve to the boiler.
Remove the diverter valve electrical connection.
Remove the spring clip “1” and remove the diverter valve “2”.
Replace in reverse order.
Replacing the Low water pressure switch
A
Before carrying out the following instructions it is advisable to protect the area and the boiler’s PCB housing
against accidental water spillage.
fig. 48
Isolate the power supply and close the Gas isolation valve to the boiler.
Turn off the Flow & Return isolation valves & drain the boiler (see system draining fig. 16).
Remove the electrical connection “1” and fastening spring clip “2”.
Remove the water pressure switch “3”.
Clean or replace the LWP switch then apply silicone grease to the 'O' ring before replacing.
1
2
1
2
3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ferroli BLUEHELIX TECH RRT 28 C and is the answer not in the manual?

Ferroli BLUEHELIX TECH RRT 28 C Specifications

General IconGeneral
BrandFerroli
ModelBLUEHELIX TECH RRT 28 C
CategoryBoiler
LanguageEnglish

Related product manuals