EasyManua.ls Logo

Ferroli BLUEHELIX TECH S 45H - User Manual

Ferroli BLUEHELIX TECH S 45H
84 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
BLUEHELIX TECH S 45H
90
700
420
ACFE
A C E
F
320
105
12012090
110
113
46 153 108
143
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
ES -
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
TR -
KULLANMA, KURULUM VE BAKİM TALIMATLAR
İ
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR -
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
RO -
INSTRUCŢIUNI DE UTILIZARE, INSTALARE ŞI ÎNTRETINERE
RU -
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ, МОНТАЖУ И ТЕХОБСЛУЖИВАНИЮ
UK -
ІНСТРУКЦІЯ З ЕКСПЛУАТАЦІЇ, МОНТАЖУ ТА ОБСЛУГОВУВАННЯ
cod. 3541G103 - Rev. 00 - 05/2017
https://tm.by
Интернет-магазин TM.by

Other manuals for Ferroli BLUEHELIX TECH S 45H

Questions and Answers

  • D
    Dr. John Taylor MDSep 10, 2025
    What does 'Sensor positioning' mean on my Ferroli BLUEHELIX TECH S 45H Boiler, and what should I do?
    • M
      Mrs. Kimberly TranSep 10, 2025
      If your Ferroli Boiler displays a 'Sensor positioning' issue, it means the heating sensor is detached from the pipe. You should check the correct positioning and operation of the heating sensor.
  • T
    Tyler MorenoAug 22, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H Boiler fan is faulty?
    • D
      Daniel ShepherdAug 23, 2025
      If you're experiencing a fan fault with your Ferroli Boiler, several factors could be responsible. First, check the 3-pin connector wiring to ensure there's a 230V power supply. If that's not the issue, examine the 5-pin connector wiring for any interruptions in the tachometric signal. Finally, the fan itself might be damaged, so inspect the fan for any signs of wear or malfunction.
  • E
    Elizabeth SantosAug 25, 2025
    Why is my Ferroli Boiler showing incorrect system water pressure?
    • V
      vhammondAug 25, 2025
      If your Ferroli boiler displays an incorrect system water pressure, it could be due to the pressure being too low, in which case you should fill the system. Alternatively, the water pressure switch might be damaged or not connected, requiring you to check the sensor.
  • D
    David HoldenAug 26, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H Boiler has high fume temperature?
    • D
      Derek VillaAug 26, 2025
      If your Ferroli Boiler is showing a high fume temperature, it means that the fume probe detects an excessive temperature. You should check the exchanger.
  • A
    Anthony HansonAug 27, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H Boiler has a Delivery sensor 1 fault?
    • X
      xballardAug 27, 2025
      If your Ferroli Boiler is showing a Delivery sensor 1 fault, it indicates that the sensor may be damaged. You should check the wiring or replace the sensor.
  • R
    Robert DuranAug 29, 2025
    What to do if my Ferroli Boiler has a Return sensor fault?
    • L
      Lauren WilliamsonAug 29, 2025
      If your Ferroli Boiler is showing a Return sensor fault, it means the sensor is damaged. You should check the wiring or replace the sensor.
  • D
    Douglas DodsonSep 18, 2025
    What does 'Card parameter fault' mean on my Ferroli Boiler, and what should I do?
    • X
      Xavier SmithSep 18, 2025
      If your Ferroli Boiler displays a 'Card parameter fault', it means there is a wrong card parameter setting. You should check the card parameter and modify it if necessary.
  • K
    Kimberly AllenSep 12, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H Boiler has a Heating sensor fault?
    • K
      Kevin GibsonSep 12, 2025
      If your Ferroli Boiler shows a heating sensor fault, the sensor is damaged. You should replace the sensor.
  • R
    Ricky BowenSep 8, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H has an External probe fault?
    • S
      Stephanie BurtonSep 8, 2025
      If your Ferroli Boiler is showing an external probe fault, it could be due to the probe being damaged or the wiring being shorted, in which case you should check the wiring or replace the sensor. It could also be due to the probe being disconnected after activating the sliding temperature, so you should reconnect the external probe or disable the sliding temperature.
  • C
    Colleen BaileySep 5, 2025
    What to do if my Ferroli BLUEHELIX TECH S 45H Boiler shows 'Supply voltage under 170V'?
    • R
      reedtravisSep 5, 2025
      If your Ferroli Boiler displays a 'Supply voltage under 170V' error, it indicates electric mains trouble. You should check the electrical system.

Ferroli BLUEHELIX TECH S 45H Specifications

General IconGeneral
Fuel TypeNatural Gas / LPG
Power Output45 kW
Max. Heating Output45 kW
DHW Output45 kW
Efficiency98%
Efficiency ClassA
Heat Exchanger MaterialStainless Steel
Max Working Pressure3 bar
Flue Diameter80/125 mm
Electrical Supply230 V
Protection RatingIPX5D
TypeCondensing