EasyManua.ls Logo

Ferroli Ferella Boil F 30 MEL User Manual

Ferroli Ferella Boil F 30 MEL
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DOMINA OASI F 24-30 E
FERELLA BOIL F 24-30 MEL
KEA AIR COMPACT E
Wall-Mounting
Gas Boiler
Airtight Chamber,
for Heating and Hot
Water with
Integrated Boiler
TECHNICAL
MANUAL
EDITION
09•2002
Question and Answer IconNeed help?

Do you have a question about the Ferroli Ferella Boil F 30 MEL and is the answer not in the manual?

Ferroli Ferella Boil F 30 MEL Specifications

General IconGeneral
Output30 kW
Warranty2 years
Fuel TypeGas
MountingWall
FuelNatural Gas

Summary

General Technical Characteristics and Data

General Warnings

Important safety precautions for installation, maintenance, and operation.

General View and Main Components

F 24 E/MEL version

Detailed illustration and key for components of the F 24 E/MEL version.

F 30 E/MEL version

Detailed illustration and key for components of the F 30 E/MEL version.

Product Framework and Internal Components

2.1 Hydraulic circuit - heating

Hydraulic diagram and explanation of the heating circuit operation.

2.2 Hydraulic circuit – tap water

Hydraulic diagram and explanation of the tap water circuit operation.

2.3 Gas circuit

Diagram and explanation of the gas circuit and its components.

Adjusting burner pressure

Procedure for adjusting minimum and maximum burner pressure settings.

Gas supply conversion

Steps for converting the unit from Natural Gas to LPG or vice versa.

2.4 Burner unit

Operation and components of the burner unit, including manifold, nozzles, and ignition.

2.5 Fume circuit

Explanation of the fume deflector, manifold, airtight chamber, and fan system.

Diaphragms

Guidelines for fitting and choosing diaphragms to maintain combustion parameters.

2.6 Electrical circuit

Overview of the electrical terminal board and wiring diagram.

Operation

3.1 Operating principle

Explanation of the boiler's operating logic for heating and hot water demand.

Control Panel

Operating Parameter Adjustment

3.5 Operating parameter adjustment

Detailed explanation of various boiler parameter adjustments via potentiometers.

Boiler parameter adjustment

Description of potentiometers P1-P5 for controlling temperature, capacity, and pressure.

Troubleshooting

Flow Diagram 1: Checking Electric Power Supply - System Pressure and Antifreeze Protection

Flowchart for diagnosing issues related to power, system pressure, and antifreeze protection.

Flow Diagram 2: Checking Hot Water Operation

Flowchart for troubleshooting hot water operational problems.

Flow Diagram 3: Checking Heating Operation

Flowchart for diagnosing issues with the heating operation.

Flow Diagram 4: Checking Fan/Fume Circuit

Flowchart for troubleshooting fan and fume circuit malfunctions.

Flow Diagram 5: Checking Ignition

Flowchart for diagnosing and resolving ignition problems.

Flow Diagram 6: Check the Modulation of the Hot Water and Heating

Flowchart for checking flame modulation in hot water and heating modes.

Related product manuals