    What to do if there is incorrect system water pressure in Ferroli DIVA F37 Boiler?
    • B
      Bonnie RomanAug 19, 2025
      If you have incorrect system water pressure in your Ferroli Boiler, it could be because: * The pressure is too low, in which case you should fill the system. * The water pressure switch is damaged or not connected, so check the sensor.
  • A
    Adam DixonAug 21, 2025
    What to do if there is overtemperature protection intervention in Ferroli DIVA F37 Boiler?
    • Y
      yknightAug 22, 2025
      If your Ferroli Boiler displays an overtemperature protection intervention, it could be due to several reasons: * The heating sensor might be damaged, so you should check its positioning and operation. * There might be no water circulation in the system, in which case you should check the circulating pump. * Air could be trapped in the system, requiring you to vent it. * The safety thermostat might have intervened, so you should check its operation.
  • T
    Travis DickersonAug 25, 2025
    Why is there no burner ignition in my Ferroli DIVA F37?
    • W
      William ShawAug 25, 2025
      If your Ferroli Boiler has no burner ignition, it could be due to several reasons: * There might be no gas supply. Check the regular gas flow to the boiler and ensure that air has been eliminated from the pipes. * There could be an ignition/detection electrode fault. Check the wiring of the electrode, ensure it's correctly positioned, and free of any deposits. * The gas valve might be faulty. Check the gas valve and replace it if necessary. * The ignition power could be too low. In this case, adjust the ignition power.
  • C
    Caitlin HernandezAug 26, 2025
    What to do if air pressure switch fails to close contacts within 20 sec. of fan activation in Ferroli Boiler?
    • T
      Thomas FernandezAug 26, 2025
      If the air pressure switch in your Ferroli Boiler fails to close contacts within 20 seconds of fan activation, it could be due to: * An open air pressure switch contact. Check the pressure switch, fan, and fan socket. * Faulty air pressure switch wiring. Inspect the wiring. * An incorrect baffle. Ensure the baffle is correct. * A flue that is obstructed or not correctly sized. Check the length of the flues and clean them.
  • C
    Cynthia HarrisAug 28, 2025
    What does flame present signal with burner off mean in Ferroli DIVA F37?
    • A
      Andrew PerkinsAug 28, 2025
      If your Ferroli Boiler displays a 'Flame present signal with burner off' message, it could be due to: * Electrode fault, so you should check the ionisation electrode wiring. * Card fault, so you should check the card.
  • J
    Jamie BrownAug 30, 2025
    Why is my Ferroli DIVA F37 Boiler experiencing exchanger protection intervention?
    • A
      Anthony HarrisAug 30, 2025
      If your Ferroli Boiler is experiencing exchanger protection intervention, it could be due to: * No system HO circulation. Check the circulating pump. * Air in the system. Vent the system.
  • C
    Christina TaylorSep 1, 2025
    How to troubleshoot a faulty gas valve in Ferroli Boiler?
    • C
      Christopher HernandezSep 1, 2025
      If your Ferroli Boiler's gas valve is faulty, it might be due to: * Disconnected wiring. Check the wiring. * A faulty gas valve. Check the gas valve and replace it if necessary.
  • M
    Michelle PattersonSep 3, 2025
    Why is there no flame after the ignition phase in my Ferroli DIVA F37?
    • E
      Elizabeth WellsSep 3, 2025
      If your Ferroli Boiler shows no flame after the ignition phase, it could be due to: * Low pressure in the gas system. Check the gas pressure. * Incorrect burner minimum pressure setting. Check the gas pressures.
  • R
    Robert GravesSep 5, 2025
    What causes delivery or DHW sensor fault in Ferroli Boiler?
    • M
      Ms. Amber Carroll DVMSep 5, 2025
      If your Ferroli Boiler shows a delivery or DHW sensor fault, it is likely the sensor is damaged. Check the wiring or replace the sensor.
  • M
    martinalyssaSep 7, 2025
    What to do if DHW sensor fault in Ferroli DIVA F37 Boiler?
    • D
      Deborah DaltonSep 8, 2025
      If your Ferroli Boiler shows a delivery or DHW sensor fault, it is likely the sensor is damaged. Check the wiring or replace the sensor.

Summary

General Remarks and Operating Instructions

1. ЗАГАЛЬНІ ЗАУВАЖЕННЏ (General Remarks)

Important safety and operational notes for boiler installation and use.

2. ІНСТРУКЦІџ З ЕКСПЛУАТАЦІЇ (Operating Instructions)

Guidance on boiler operation, including introduction and control panel.

2.4 Adjustments

Procedures for adjusting boiler settings like temperature and modes.

Installation Guide

3. МОНТАЖ (Installation)

Comprehensive guide to installing the boiler unit.

3.3 Plumbing connections

Instructions for connecting water pipes and system characteristics.

3.4 Gas connection

Procedures for connecting the gas supply to the boiler.

Service and Maintenance

4. SERVICE AND MAINTENANCE

Procedures for boiler servicing, maintenance, and troubleshooting.

4.3 Maintenance

Procedures for regular servicing and inspection of the boiler.

4.4 Troubleshooting

Guidance on diagnosing and resolving boiler faults.

Technical Data and Characteristics

5. TECHNICAL DATA AND CHARACTERISTICS

Detailed specifications and performance data for the boiler models.

5.4 Technical data table

Comprehensive table of technical specifications and performance data.

Ferroli DIVA F37 Specifications

General IconGeneral
Power Output37 kW
DHW Output37 kW
Efficiency ClassA
ERP RatingA
Dimensions (HxWxD)700 x 400 x 330 mm
IgnitionElectronic
Heat Exchanger MaterialStainless Steel
TypeCombi
Fuel TypeNatural Gas