EasyManua.ls Logo

Ferroli DIVAtech F 24 D - User Manual

Ferroli DIVAtech F 24 D
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cod. 3541B072 — Rev. 00 - 11/2016
DIVAtech F 24 D
700
400
808050557560
178
126
Ø
110
÷
120
120
725
676
50 75 55 50 80 75
93
114
Ø
30
Ø
30
Ø
24.5
Ø
24.5
Ø
24.5
FABCD E
ABCDE
85
115
90
110
195
266
F
330
A
B
C
D
E
F
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
%

Questions and Answers

  • M
    Miss Kelsey TurnerAug 20, 2025
    How to fix no burner ignition on my Ferroli Boiler?
    • S
      Sean CaseyAug 20, 2025
      If the Ferroli Boiler burner doesn't ignite, the possible causes include: no gas supply, in which case you should check the gas flow and ensure air is purged from the pipes; a fault with the ignition/detection electrode, requiring you to inspect the wiring and positioning, and clean any deposits; a faulty gas valve, which may need replacement; disconnected gas valve wiring, which you should check; or low ignition power, which needs adjustment.
  • R
    rebecca83Aug 22, 2025
    What to do if the overtemperature protection activates on a Ferroli Boiler?
    • G
      gwendolyn57Aug 22, 2025
      If the Ferroli Boiler activates overtemperature protection, it might be due to a damaged heating sensor. Check its positioning and operation. Another cause could be lack of water circulation in the system, so inspect the circulating pump. Air in the system can also trigger this, thus you should vent the system.
  • M
    Michael MillerAug 25, 2025
    Why is there no flame after ignition phase in my Ferroli DIVAtech F 24 D?
    • Q
      qbrooksAug 25, 2025
      If your Ferroli Boiler shows no flame after the ignition phase, it could be due to low gas pressure in the gas system, so check the gas pressure. It may also be due to the burner minimum pressure setting, so check the pressures.
  • C
    Carol KleinAug 26, 2025
    What to do if Ferroli Boiler shows flame when burner is off?
    • J
      Julie AlvaradoAug 27, 2025
      If the Ferroli Boiler shows a flame present signal even when the burner is off, it could be due to an electrode fault. In this case, check the ionization electrode wiring. Alternatively, it might be a card fault, so check the card.
  • R
    reynoldsandreAug 28, 2025
    How to troubleshoot a gas valve fault on a Ferroli DIVAtech F 24 D Boiler?
    • C
      Caitlin LambertAug 28, 2025
      If the Ferroli Boiler displays a gas valve fault, the wiring might be disconnected, so check the wiring. Alternatively, the gas valve itself may be faulty and require replacement; in this case, check the gas valve.
  • J
    Joyce RomeroAug 29, 2025
    Why does my Ferroli DIVAtech F 24 D Boiler show incorrect system water pressure?
    • S
      Stephen CruzAug 30, 2025
      If your Ferroli Boiler indicates incorrect system water pressure, the pressure may be too low, requiring you to fill the system. The water pressure switch might also be damaged or disconnected, so check the sensor. Additionally, a damaged probe or shorted wiring could be the cause, so check the wiring or replace the sensor. Finally, the probe may be disconnected after activating the sliding temperature, so reconnect the external sensor or disable the sliding temperature.
  • S
    steven48Aug 31, 2025
    What causes a combustion control fault in a Ferroli DIVAtech F 24 D?
    • T
      tuckershellyAug 31, 2025
      If the Ferroli Boiler shows a combustion control fault, the fan or fan wiring could be faulty, so check the fan and fan wiring. A faulty baffle could also be the cause, so check the baffle and replace it if necessary. Another possibility is that the flue is not correctly sized or is obstructed, so check the flue.
  • P
    Patricia BeckSep 2, 2025
    What to do if my Ferroli DIVAtech F 24 D shows a delivery sensor 1 fault?
    • T
      Terrance SanchezSep 2, 2025
      If the Ferroli Boiler has a delivery sensor 1 fault, it could be that the sensor is damaged. Check the wiring or replace the sensor.
  • J
    John TurnerSep 4, 2025
    How to fix a delivery sensor 2 fault on Ferroli DIVAtech F 24 D Boiler?
    • P
      Paul CarsonSep 4, 2025
      If the Ferroli Boiler has a delivery sensor 2 fault, it could be that the sensor is damaged. Check the wiring or replace the sensor.
  • C
    Christine CookSep 6, 2025
    What causes a DHW sensor fault in a Ferroli DIVAtech F 24 D Boiler?
    • J
      Jessica BrooksSep 6, 2025
      If the Ferroli Boiler displays a DHW sensor fault, the sensor may be damaged. Check the wiring or replace the sensor.

Summary

General Warnings and Safety

Operating Instructions and Controls

Boiler Introduction and Panel Overview

Details boiler features and explains the control panel functions, symbols, and display.

Startup, Shutdown, and Modes

Guides on connecting power, turning the boiler on/off, and selecting modes.

Temperature and Comfort Adjustments

Covers DHW, room temp, eco/comfort selection, and sliding temperature adjustments.

Installation Guidelines

General Installation Requirements

Covers general instructions, place of installation, and ventilation requirements.

Plumbing, Gas, and Electrical Connections

Details water, gas, and electrical connections, including terminal block access.

Fume Ducting and Baffles

Explains fume duct types, installation, and the use of baffles.

Flue System Configurations

Coaxial Pipe Connections

Details coaxial pipe types, starting accessories, and baffles for installation.

Separate Pipe Connections

Covers separate pipe types, starting accessories, baffles, and loss calculation.

Service and Maintenance

Operational Adjustments and Gas Conversion

Covers gas conversion, TEST mode activation, and burner pressure adjustments.

Startup Procedures and Operational Checks

Details checks before and during boiler operation for safe startup.

Periodic Maintenance Checks

Outlines essential annual checks for control devices and system integrity.

Troubleshooting and Diagnostics

Boiler Self-Diagnosis System

Explains how the boiler's advanced self-diagnosis system indicates faults.

Fault Code Reference

Lists fault codes, possible causes, and suggested cures for boiler issues.

Technical Specifications

Component Identification

Provides a key to identify main components and diagrams of water circuits.

Technical Data and Performance

Detailed Technical Specifications

Presents a table with key technical data, including capacities and pressures.

Performance Diagrams

Illustrates pressure-power relationships and pump head/pressure loss curves.

Electrical Schematics

Wiring Diagram

Shows the detailed electrical circuit connections for the boiler's components.

Regulatory Compliance

Declaration of Conformity

States the boiler's compliance with relevant EU directives for gas, efficiency, and safety.

Ferroli DIVAtech F 24 D Specifications

General IconGeneral
BrandFerroli
ModelDIVAtech F 24 D
CategoryBoiler
LanguageEnglish

Related product manuals